Siemens siemens network router mc35 ユーザーズマニュアル

ページ / 65
Remote-SAT User's Guide
MC35_SAT_01_v02.00
Page 34 of 65
11.01.2002
1.4.11 AT^SSTGI  Remote-SAT Get Information – Get Inkey (34)
Write command
AT^SSTGI=34
This command is to be used upon receiving an unsolicited result code
^SSTN:34.
The TA is asked to prompt the user for an input, which is a single character.
Help can be requested by the user, if available.
Text and an Icon Identifier can be passed to the TA to display to the user.
Response
^SSTGI: <cmdType>, <commandDetails>, <text>, <iconQualifier>, <iconId>
<CR> <LF>
Parameters
<cmdType>
34 – Proactive command ID, see Table 1
<commandDetails>
Unsigned Integer, range 0 – 255, used as a bitfield.
bit 1:
0 = digits (0-9, *, # and +) only
1 = alphabet set;
bit 2:
0 = SMS default alphabet (GSM character set)
1 = UCS2 alphabet
bit 3:
0 = character sets defined by bit 1 and bit 2 are 
enabled
1 = character sets defined by bit 1 and bit 2 are
disabled and the "Yes/No" response is
requested
bits 4-7: = RFU
bit 8:
0 = no help information available
1 = help information available
<text>
String as prompt for text.
<iconQualifier>
Unsigned Integer, range 0 – 255, used as a bitfield.
bit 1:
0 = icon is self explanatory and replaces text
1 = icon is not self-explanatory and shall be
displayed with the text
Determined value only if associated icon id is
not 0 (an icon exists).
bits 2-8: = RFU
<iconId>
0-255, 0: no icon
Reference
Siemens
Note