1.5.2.8  AT^SSTR  Remote-SAT Response – Play Tone (32)
Write command
AT^SSTR=32,
<status>
The TA acknowledges the successful receipt of the proactive command.
Response
OK
Parameters
<cmdType> 32 – Proactive command ID, see Table 1
<status>
Unsigned Integer, range 0-255
0
Command performed successfully
16
Proactive SIM session terminated by user
32
TA currently unable to process command
132
TA currently unable to process command because
screen is busy.
Notes: