Sub-Zero 36gasrangetop ユーザーズマニュアル

ページ / 5
Planning Information
36"
(914)
Gas Rangetops
M O D E L S   R T 3 6 6   /   R T 3 6 4 C   /   R T 3 6 4 G   /   R T 3 6 2 F
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
I N S T A L L A T I O N S P E C I F I C A T I O N S
D I M E N S I O N S
Overall Width of Rangetop
36" (914)
Finished Rough Opening Width
36
1
/
4
" (921)
Location of Electrical and Gas Supply
Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
Refer to the Wolf Design Guide for additional specifications.
14"
(356)
8" 
(203)
36
1
/
4
(921)
FINISHED ROUGH OPENING WIDTH
3
/
4
(19) PLATFORM
TOP VIEW
OF PLATFORM
E
G
8" 
(203)
3"
(76)
BACK WALL
1
/
2
"
(13)
 2
3
/
4
"
(70)
ISLAND INSTALLATIONS: 12" (305) MINIMUM
CLEARANCE FROM BACK OF RANGETOP TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
0" (0) TO NON-COMBUSTIBLE MATERIALS
3
/
4
(19) PLATFORM
 9
1
/
2
(241)
OPENING
HEIGHT
24" 
(610)
13"
max
(330)
36"
(914)
18"
min (457)
TO COUNTERTOP
LOCATION OF
GAS AND ELECTRICAL
SUPPLY CUT-OUT
WITHIN SHADED AREA
THROUGH BOTTOM OF
PLATFORM
30"
min (762)
TO
 36"
max (914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
6"
min (152)
TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
30"
min (762)
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
36"
min (914)
 FOR CHARBROILER
VENTILATION HOOD