Ariston a1200wd ユーザーズマニュアル

ページ / 16
The first wash cycle
Once the appliance has been installed and before you
use it for the first time, run a wash cycle without 
detergent and no laundry, setting the 90˚C 
programme without a pre-wash cycle.
Models
A1600WD, A1400SWD, 
A1400WD, A1200WD
59.5cm wide
Dimensions
85cm high
60cm deep
Capacity
from 1 to 6kg
Electric
voltage 220/240 Volts  50Hz
connections
maximum absorbed power:
1700W-2100W
Water
maximum pressure 1 MPa (10 bar)
connections
minimum pressure 0.05 MPa (0.5 bar)
drum capacity 53 litres
Spin Speed
up to 1600 rpm -  A1600WD
up to 1400 rpm -  A1400SWD, 
A1400WD
up to 1200 rpm -  A1200WD
Control
programme 3
programmes
temperature 60˚C
according to
IEC50229
-
dry run with a 1kg load followed by 
directive
a 5kg load for model A1600WD
-
dry run with a 2kg load followed by 
a 4kg load for models A1400SWD,
A1400WD and A1200WD
This appliance is compliant with the
following European Community
Directives:
- 72/23/CEE of 19/02/73 
(Low Voltage) and subsequent amendments.
- 89/336/CEE of 03/05/89 (Electromagnetic
Compatibility) and subsequent amendments.
Drainage connections
A. Connect the drain 
hose, without kinking it, 
to a draining duct or a 
wall drain fixed at a 
height between 65 and 
100cm from the floor. 
Use the curved bracket,
if reqired.
B. Alternatively, place 
it over the edge of a 
basin, sink or tub, 
fastening the hose 
supplied to the tap.  
!
The free end of the hose should not be under water.
!
We advise against the use of hose extensions. In
case of absolute need, the extension must have the
same diameter as the original hose and must not
exceed 150cm in length.
Electrical connections
Before plugging the appliance into the mains socket,
make sure that:
the socket is earthed and in compliance with the 
applicable law.
the socket is able to sustain the appliances 
maximum power load indicated in the Technical 
Details table (
on the right
).
the supply voltage is included within the values 
indicated in the Technical Details table (
on the 
right
).
the socket is compatible with the machines plug.  
If this is not the case, replace the socket or the 
plug.
!
The machine should not be installed in an outdoor
environment, not even when the area is sheltered,
because it may be very dangerous to leave it exposed
to rain and thunderstorms.
!
When the machine is installed, the mains socket
must be within easy reach and should be connected
to a suitable electrical supply.
!
Do not use extensions or multiple sockets.
!
The power supply cable must never be bent or dan-
gerously compressed.
!
The power supply cable must only be replaced by
an authorised serviceman.
!
The company denies all liability if and when these
norms are not respected.
3
A
B
Technical Details
GB
Installation