Alliance Laundry Systems bf85pv ユーザーズマニュアル

ページ / 119
F232058
45
Section 3
Maintenance
Routine maintenance maximizes operating 
efficiency and minimizes downtime. The 
maintenance procedures described below will 
prolong the life of the machine and help 
prevent accidents.
Daily, weekly, monthly, and quarterly 
checklists are provided at the end of this 
section. Laminate the checklists to preserve 
them for repeated copying. Operators and 
technicians are encouraged to add checks 
specific to their machine’s particular 
application. When possible, space is provided 
on the checklists for this purpose. 
The following maintenance procedures 
must be performed regularly at the
required intervals.
Daily
Beginning of Day
1. Inspect water inlet valve hose 
connections on the back of the machine 
for leaks.
2. Inspect steam hose connections for leaks, 
where applicable.
3. Verify that insulation is intact on all 
external wires and that all connections are 
secure. If bare wire is evident, call a 
service technician. 
4. Check door interlock before
starting operation: 
a. Attempt to start the washer with the 
door open. The washer should not start 
with the door open.
b. Close the door without locking it and 
attempt to start the washer. The washer 
should not start with the door unlocked.
c. Close and lock the door and start a 
cycle. Attempt to open the door while 
the cycle is in progress. The door 
should not open.
If the door lock and interlock are 
not functioning properly, call a 
service technician.
The AC drive box cover and fan filter must 
be in place for the fan to properly cool the 
AC inverter drive. Failure to observe this 
warning will void the warranty and could 
lead to expensive AC inverter drive repair.
SW038
WARNING
Replace all panels that are removed to 
perform service and maintenance 
procedures. Do not operate the machine 
with missing guards or with broken or 
missing parts. Do not bypass any 
safety devices.
SW019
CAUTION