ELECTRICAL REQUIREMENTS
For 50 Pound (22 kg) Tumblers
ELECTRIC DRYING TUMBLERS
NOTE: DO NOT use aluminum wire.
ELECTRIC DRYING TUMBLERS
240 V, 3 Phase
50 Hz.
380 V, 3 Phase
50 Hz.
415 V, 3 Phase
50 Hz.
Minimum Wire Size
3 AWG (26.67 mm²)
6 AWG (13.32 mm²)
6 AWG (13.32 mm²)
AMP Rating
78 AMP
48 AMP
45 AMP
Circuit Breaker
80 AMP
50 AMP
50 AMP
Poles
3
3
3
Figure 13
GAS AND HIGH PRESSURE STEAM DRYING TUMBLERS
208V / 240 V
1 Phase, 50 Hz.
208 / 240 V
3 Phase, 50 Hz.
380 / 415 V
3 Phase, 50 Hz.
Minimum Wire Size
14 AWG (2.081 mm²)
14 AWG (2.081 mm²)
14 AWG (2.081 mm²)
Circuit Breaker
15 AMP
15 AMP
15 AMP
Poles
2
3
3
Figure 12
Figure 11
Heat Source
Electrical Specs
Wires Required and Terminal Block Connection
Non-Reversing Models
Gas & Steam
230/50/1
L1
L2
Ground to PE Busbar
Steam
380-415/50/3
L1
L2
L3
Ground to PE Busbar
Electric
230/50/1
L1
L2
Ground to PE Busbar
Electric
380-415/50/3
L1
L2
L3
Ground to PE Busbar
Reversing Models
Gas & Steam
230/50/1
L1
L2
Ground to PE Busbar
Gas & Steam
380-415/50/3
L1
L2
L3
Ground to PE Busbar
Electric
230/50/3
L1
L2
L3
Ground to PE Busbar
Electric
380-415/50/3
L1
L2
L3
Ground to PE Busbar
GAS AND HIGH PRESSURE STEAM DRYING TUMBLER