Ariens sno-thro 924337 st11528dle ユーザーズマニュアル

ページ / 32
GB - 20
CHECK DUAL HANDLE 
INTERLOCK 
Without the engine running, press down 
(engage) both clutch levers. Release 
attachment clutch lever. Attachment clutch 
should remain engaged until traction clutch 
lever is released, then both clutches must 
disengage.
CHECK FASTENERS
Make sure all hardware is tightened properly.
CHECK CLUTCHES
Auger / impeller must stop within 5 seconds 
when attachment clutch/impeller brake lever is 
released.
Wheels must stop quickly when traction drive 
clutch lever is released.
If clutches do not engage or disengage 
properly, adjust or repair before operation (see 
Service and Adjustments).
CLEAN ENGINE
Refer to Engine Manual for detailed 
instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked 
every 5 hours of operation. Oil level MUST be 
maintained in safe operating range on dipstick 
at all times or engine damage will result (See 
Engine Manual).
Park unit on a level surface. Refer to Engine 
Manual for detailed instructions.
CHANGE ENGINE OIL
Change oil after first 2 hours of operation, 
thereafter change oil every 25 hours (more 
often if required). Refer to Engine Manual for 
detailed instructions.
Run engine just prior to changing oil. Warm oil 
will flow more freely and carry away more 
contamination. Remove the oil drain plug from 
the rear of the unit and tip the unit back to help 
drain all the oil.
CHECK TIRE PRESSURE
Keep tires at pressure listed on the tire 
sidewall.
CHECK AUGER GEARCASE 
IMPORTANT: Proper oil level must be 
maintained.
Gear cases are filled to the correct level at the 
factory. Unless there is evidence of leakage, 
no additional lubricant should be required. 
Check oil level each season or every 25 hours 
of operation.
To ensure adequate lubricant level:
1. Remove filler plug (Figure 14). Lubricant 
must be at least up to bottom of lubricant 
filler hole with unit resting on a 
level-surface.
2. Add lubricant if required. Allow oil to drain 
to level of plug and replace plug. 
IMPORTANT: Use only Ariens special gear 
lubricant L-2 (Part Number 00008000).
GENERAL LUBRICATION
IMPORTANT: Wipe each fitting clean before 
and after lubrication.
IMPORTANT: DO NOT allow grease or oil to 
get on friction disc, friction plate or belts.
NOTE: Apply Stens Mix Hi-Temp Grease or 
equivalent to the lubrication fittings. See 
Service Parts.
Sno-Thro should be lubricated (Figure 15) at 
beginning of season or every 25 operating 
hours.
Auger Shaft
NOTE: To grease auger shaft, remove shear 
bolt nuts, and shear bolts. Turn auger on shaft 
while applying grease at zerk fittings. Replace 
shear bolt per instructions in Service and 
Adjustments
.
Figure 14
1. Auger Gearcase - Cast Iron
2. Oil Fill and Drain Plug
3. Auger Gearcase - Aluminum
3
2
1