ICOM id-1 ユーザーズマニュアル

ページ / 124
53
7
TRANSMIT AND RECEIVE— VOICE
New2001
■ Monitor function
The monitor function releases all squelch mutes, noise
squelch, tone squelch, digital code squelch and digital call
sign squelch, to monitor the signal on the displayed fre-
quency.
➥ Click [MONI] in the application (main screen); or push and
hold [SQL] on the RC-24 to activate the monitor function.
• “MONI” and “
” appear for FM mode, “MONI” appears for
DV and DD mode operation when the function ON. (main screen)
• “
” appears on the RC-24 function display while holding [SQL]
for FM operation.
• The displayed frequency shifts when duplex (RP– or RP+) is set.
D
Monitoring mode selection
Under normal settings, an FM mode signal cannot be heard,
even when the monitor is turned ON. There is an exception,
and this is when you have the Digital monitor set to the Ana-
log mode. This will allow an FM mode signal to "Break-in" dur-
ing digital communications. 
• Setting from the application
q Displays set mode screen by performing one of the follow-
ing operations.
- Select “Edit SetMode(C)...” in view menu.
- Click “
” button in tool bar.
- Click [SET].
- Press [F7] key on the PC keyboard.
w Double click “Digital Monitor” cell, then select the desired
monitoring mode from “DIGITAL” and “ANALOG.”
• ANALOG: FM mode, DIGITAL: Digital
• To close the screen, click “
” or repeat the operation as step q.
Double click the Digital. 
Monitor cell, then select 
the desired monitoring 
mode.
[SQL]
Click
Appears
BUSY