For 460 W Power Supply:
526 W (at 100 VAC),
505 W (at 200 VAC)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Maximum
For 1200 W Power Supply:
3530 BTU/hr (at 100 VAC),
4600 BTU/hr (at 200 VAC)
For 750 W Power Supply:
2925 BTU/hr (at 100 VAC),
2812 BTU/hr (at 200 VAC)
For 460 W Power Supply:
1794 BTU/hr (at 100 VAC),
1725 BTU/hr (at 200 VAC)
Power Specifications
Power Specifications
Power Specifications
Power Specifications
NOTE: 
NOTE: 
NOTE: 
NOTE: To review typical system power ratings use the HP Power Advisor
which is available online located at url: www.hp.com/go/proliant-energy-
efficient or 
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
Rated Steady-State Power For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
Maximum Peak Power
For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
QuickSpecs
HP X1000 G2 Network Storage Systems
HP X1000 G2 Network Storage Systems
HP X1000 G2 Network Storage Systems
HP X1000 G2 Network Storage Systems
Technical Specifications
DA - 13839   North America — Version 7 — July 8, 2011