EP-15 Fluid Level Calibration 
The default calibration for the EP-15 Fluid Level is just as accurate as 
standard fluid level gauges. If, however, the tank has an irregular 
shape or greater accuracy is needed, calibration is recommended. There 
are three calibration options: 2-Point, 3-Point and 5-Point. 
2-Point Calibration 
A 2-point calibration is best suited for rectangular or square-shaped 
tanks, where the capacity of the top half of the tank matches the capac-
ity in the lower half of the tank. In a two-point calibration, you will set 
two points, one each for empty and full levels. You can begin calibra-
tion at either of the two points, but we recommend starting with an 
empty tank. You will fill the tank to complete calibration.  
1. Press 
MENU| MENU
, use 
↓ ↑  to select 
NMEA
 
2000
 and press 
ENT
2. Highlight 
B
US 
S
ETUP
 and press 
ENT
, which will open the Bus Configu-
ration menu. A list of network devices will be at the top of the page.   
3. Select the EP-15 Fluid Level and press 
ENT
4. Press 
↓ to select 
C
ALIBRATE
 and press 
ENT
. The Device Calibration 
menu will appear. Instructions on Calibration will be listed at the top 
of the menu.  
5. Highlight
 N
UM 
P
TS
,
 
press
 ENT 
and select
 2. 
Press 
ENT
6.
 
Select
 F
LUID 
L
EVEL
, press
 ENT
, then select
 E
MPTY 
L
EVEL
 
and press 
ENT.  
7. Make sure the fuel tank is empty, highlight 
C
ALIBRATE
 and press 
ENT
The following message will appear: Empty Level Calibration Com-
pleted. 
Press ENT.
 
8. 
Fill up your tank, highlight
 F
LUID 
L
EVEL
 
and press
 ENT
9. 
Select
 F
ULL 
L
EVEL
 
and press
 ENT
Highlight 
C
ALIBRATE
 
and press
 ENT.  
10. 
The following message will appear
Full level Calibration Com-
pleted.
 
Press 
ENT
, then press 
EXIT
 repeatedly to get back to the main 
display.