HP StorageWorks X1500 G2 BV858A ユーザーズマニュアル

製品コード
BV858A
ページ / 54
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
X1600 G2
X1600 G2
X1600 G2
X1600 G2
 
 
 
 
 
 
 
 
 
 
 
 
System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (H x W x D)
(with bezel)
3.44x 17.64 x 27.50 in (8.75 x 44.80 x 69.88cm)
Weight
Weight
Weight
Weight
(approximate)
Maximum
Maximum
Maximum
Maximum
(all hard drives, power
supplies and processors
installed)
51.5 lb (19.22 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100 - 240 VAC
Rated Input Current
9.10 A (at 100 VAC),
4.5 A (at 200 VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
910 W (at 100 VAC),
900 W (at 200 VAC)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Maximum
3107.82 BTU/hr (at 100 VAC),
3073.67 BTU/hr (at 200 VAC)
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
50° to 95°F (10° to 35°C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).
Non-operating
-22° to 140° F (-30° to 60° C). Maximum rate of
change is 36° F/hr (20° C/hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 82.4° F (28° C)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 101.7° F (38.7°
C) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
10,000 ft (3050 m). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 1500
ft/min (457 m/min).
Non-operating
30,000 ft (9144 m). Maximum allowable
altitude change rate is 1500 ft/min (457 m/min).
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
QuickSpecs
HP X1000 G2 Network Storage Systems
HP X1000 G2 Network Storage Systems
HP X1000 G2 Network Storage Systems
HP X1000 G2 Network Storage Systems
Technical Specifications
DA - 13839   North America — Version 7 — July 8, 2011
Page 49