Metrologic Instruments IS4823 ユーザーズマニュアル
27
USB Decode PCB, 5V
12-Pin ZIF Connector
Pin
Signal Name
Function
1
No Connect No Connection
2
+5.0V
Power: Supply Voltage Input, +5.0V ± 5%
3
GND
Ground: Power and Signal Ground
4
D-
Input: USB D- Signal
5
<reserved>
Pin Function Reserved
6
D+
Input: USB D+ Signal
7
<reserved>
Pin Function Reserved
8
PWRDWN
Output: Active High = Engine is in Power Down Mode
9 nBEEPER
Output: Active Low, Signal Capable of Sinking Current
See Detailed Electrical Specifications starting on page 23.
See Detailed Electrical Specifications starting on page 23.
10 nGood
Scan
Output: Active Low, Signal for Sinking Current (Good Scan)
See Detailed Electrical Specifications starting on page 23.
See Detailed Electrical Specifications starting on page 23.
11 nEXT
Wake
Input: Active Low, Wakes Engine from Power Down or
Sleep Mode
Sleep Mode
12 EXT
Trig
Input: Active Low, Signal Used as Trigger Input to Activate
the Engine
the Engine
10-Pin ZIF Connector
Pin
Signal Name
Function
1 SDA
I
2
C Data (Bi-Directional) – Devices Function as Auxiliary
Devices
2
GND
Ground: Power and Signal Ground
3
GND
Ground: Power and Signal Ground
4 Scan
Sense
Level changes from High to low or low to high when the
laser changes direction at the start of the scan line
laser changes direction at the start of the scan line
High = Bar
5 Data
Low = Space
High = Engine OFF
High = Engine OFF
6 Scan
Enable
Low = Engine ON
High = Laser OFF
High = Laser OFF
7 Laser
Enable
Low = Laser ON
8 NC
No
Connection
9
+5.0V
Power: Supply Voltage Input, +5.0V ± 5%
Figure 19.
10 SCL
I
2
C Data (Bi-Directional) – Devices Function as Auxiliary
Devices