Metrologic Instruments MS1690 ユーザーズマニュアル

ページ / 52
 
 
10 
I
NSTALLING THE 
S
CANNER TO THE 
H
OST 
S
YSTEM
 
 
IBM MS1690-11 
 
1.  Turn off the host device.  
 
2.  Plug the male 10-pin RJ45 end of the 
MVC cable into the 10-pin socket on 
the Focus.  You will hear a ‘click’ 
when the connection is made. 
 
3.  Connect the other end of the MVC 
cable to the host device. 
 
4.  Turn on the host device. 
 
5.  Focus will start to initialize.   
All LEDs (yellow, white, and blue) will 
light for approximately 2 seconds then 
start to alternately flash.  When the 
scanner has finished initializing the 
LEDs will stop flashing and the unit 
will beep 3 times indicating that the 
scanner is ready for use.  
 
 
 
 
 
 
 
 
Plugging the scanner into a port on the host system does not guarantee 
that scanned information will be communicated properly to the host 
system.  The scanner is shipped from the factory configured with default 
settings.  Please refer to the MetroSelect Single-Line Configuration 
Guide (
MLPN 
00-02544) or MetroSet2’s help files for instructions on 
changing the scanner’s configuration.  In addition, please check that the 
scanner and host system are using the same communication protocol.  
 
 
Caution:  
To maintain compliance with applicable standards, all circuits connected to the scanner must 
meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC 60950. 
 
To maintain compliance with standard CSA-C22.2 No. 60950-00/UL 60950 and norm EN/IEC 
60950, the power source should meet applicable performance requirements for a limited 
power source.  
 
Figure 9.