Maytag mde-mdg21pra ユーザーズマニュアル

ページ / 66
©2004 Maytag Appliances Company
16022904 Rev. 0
13
Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.
General Specifications
Wattage Specifications
Exhaust Ducts
Capacity
6.0 Cubic Feet
One washer load is a full dryer load
Motor
Thermo-protected against overload auto-reset
1/4 HP, 120 Volt, 60 Hz
Air Flow
Cubic feet per minute exhausted from dryer
220 CFM
Tumbler
Revolution per minute
52 RPM
Rotation
Drum Turning, when viewed from the front
Clockwise
Heat Source
•  Electric
• 240 volt, 5600 watts, 30 amp fuse
• Gas
• Single port burner 24,000 BTU/hr.
    direct ignition, automatic shut-off
Exhaust
Venting size
4"(10.2 cm) duct, rigid aluminum
duct work.  (See installation instruc-
tions that are provided with the
product for additional information.)
Makeup Air
Free opening
Requires 30 sq. in. per dryer pocket
Static Pressure
Single unit exhausting, 4" round rigid
Should not exceed 0.92" or less
than 0 water column inches
DESCRIPTION
WATTS
Gas Dryer
350 Maximum without igniter
Electric
5900 (240V)/5600 208V)
Heating Element
5600 (240V)/5100 (208V)
Igniter 
(NOTE:  Ohm room temperature 180-400)
600