Mobile home installations require:
Metal exhaust system hardware, which is available for 
purchase from your dealer.
Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.
Drain System
The washer/dryer can be installed using the standpipe drain 
system (floor or wall), the laundry tub drain system, or the floor 
drain system. Select the drain hose installation method you need. 
See “Alternate Parts.”
Standpipe drain system - wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe of 
2" (51 mm). The minimum carry-away capacity can be no less than 
17 gal. (64 L) per minute. A 2" (51 mm) diameter to 1" (25 mm) 
diameter standpipe adapter kit is available. See “Alternate Parts.”
The top of the standpipe must be at least 39" (991 mm) high and 
no higher than 96" (2.4 m) from the bottom of the washer.
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top 
of the laundry tub must be at least 34" (864 mm) above the floor 
and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system (view D)
The floor drain system requires a siphon break that may be 
purchased separately. See “Alternate Parts.”
The siphon break must be a minimum of 28" (711 mm) from the 
bottom of the washer. Additional hoses might be needed.
Electrical Requirements - U.S.A.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in 
conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances. 
A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt 
electrical supply, if specified on the serial/rating plate) on a 
separate 30-amp circuit, fused on both sides of the line. A 
time-delay fuse or circuit breaker is recommended. Connect 
to an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit. 
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
Electrical Connection
To properly install your washer/dryer, you must determine the type 
of electrical connection you will be using and follow the 
instructions provided for it here.
This dryer is manufactured ready to install with a 3-wire 
electrical supply connection. The neutral ground wire is 
permanently connected to the neutral conductor (white wire) 
within the dryer. If the dryer is installed with a 4-wire electrical 
supply connection, the neutral ground wire must be removed 
from the internal ground connector (green screw), and secured 
under the neutral terminal (center or white wire) of the terminal 
block. When the neutral ground wire is secured under the 
neutral terminal (center or white wire) of the terminal block, the 
dryer cabinet is isolated from the neutral conductor.
If local codes do not permit the connection of a neutral ground 
wire to the neutral wire, see “Optional 3-wire connection” in 
the “Electrical Connection - U.S.A. Only” section. 
A 4-wire power supply connection must be used when the 
appliance is installed in a location where grounding through 
the neutral conductor is prohibited. Grounding through the 
neutral is prohibited for (1) new branch-circuit installations, 
(2) mobile homes, (3) recreational vehicles, and (4) areas 
where local codes prohibit grounding through the neutral 
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with clothes 
dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt 
minimum. The cord should be type SRD or SRDT and be at 
least 4 ft (1.22 m) long. The wires that connect to the dryer 
must end in ring terminals or spade terminals with upturned 
ends.
A UL listed strain relief.
39"
(991 mm)
A
B
D
C
34"
(864 mm)