3.2
CONFIGURING DIP-SWITCHES   
PI
SA
The 10/100M2 plug-in module has two board-mounted DIP-switches.  The standalone unit has one bank of
DIP-switches.  The locations of the DIP-switches are illustrated below.
Switch 1
Switch 8
Left
Switch 1
Switch 8
Bank 2
Bank 1
Right
SW1
SW8
Up
Down
Bank 1
DIP-switch Locations
3.2.1
Board-Mounted Bank 1 Settings   
PI
SA
DIP-switch Bank 1 is available on both the plug-in and standalone modules.  The table indicates the position
of the switch; Left/Down or Right/Up.  As indicated in the DIP-switch location diagram, Left and Right
refers to the plug-in module and Down and Up refers to the standalone module.
PI
 
(Left/Right)
SA
 
(Up/Down)
Switch
Left/Down
(Factory Default)
Right/Up
SW1
  Off:
  Pause Disable
  On:
  Pause Enable
SW2
  FDX:
  Fiber Full-Duplex
  HDX:
  Fiber Half-Duplex
SW3
  AN:
  UTP Auto-Negotiate
  Man:
  UTP Manual
SW4
  100:
  UTP 100Mbps
  10:
  UTP 10Mbps
SW5
  FDX:
  UTP Full-Duplex
  HDX:
  UTP Half-Duplex
SW6 - SW8
See Link Mode DIP-Switch Table in Section 3.2.1.6
3.2.1.1
SW1 - Pause Disable/Enable “Off/On”
When a port is operating in auto-negotiation, its Pause operation mode is determined by the Pause capability
advertised during auto-negotiation between itself and the link partner.  The port advertises its Pause capability
during auto-negotiation based on the Pause Disable/Enable DIP-switch setting.  Setting the Pause DIP-switch to
Page 6