If an error occurs a fault message will appear in the right display. Minor problems
can be fixed without a service call.
Message
Possible fault
Fix
Chamber empty -
please refill
The selected coffee chamber is empty.
Fill with coffee capsules.
Please fill with fresh water This is a reminder to fill the water tank
with fresh water when the machine is
turned on.
Please set the time of day The machine was disconnected from
the power supply and the time of day
needs to be reset.
Set the time of day.
Empty drip tray and clean
contacts
The drip tray is full and/or the metal
contact sensors on the tray are soiled.
Empty and clean the drip tray.
Clean and dry the contacts.
Please use descaling
funnel and close the door
The capsule plate needs to be taken out
and replaced by the descaling funnel.
Remove the capsule plate and
insert the colored funnel.
Please insert capsule
plate
The capsule plate or perforator are
missing or the descaling funnel is still in
the machine.
Insert the capsule plate or
perforator.
Please insert carousel
The carousel is missing or the sensor
under the carousel tray is soiled.
Insert the carousel and clean
the sensor with a cloth.
Please open the valve
Steam cannot be supplied if the steam
valve is closed.
Press the steam lever down.
Please close the valve
The steam lever is still pressed down.
Push the steam lever up.
Maintenance required
The capsule carousel needs to be
replaced after about 15,000 cups of
coffee.
Turn the left jog shuttle to
"Settings". Turn the right jog
shuttle to maintenance and
change the perforator (see
"Common coffee system care -
Maintenance").
Confirm to start
The selected process is prompted to
start.
Press the right jog shuttle.
Confirm to continue
The descaling needs to be continued.
Press the right jog shuttle.
Empty
A coffee chamber was selected which
has not been allocated to a coffee type.
Allocate a type of coffee to the
chamber.
No. of uses until
descaling has to be done
The machine counts the number of
drinks made before descaling has to be
carried out. Once this number reaches
zero, the machine locks until the
descaling process has been
successfully completed.
Descale the machine
(see "Descaling the
appliance").
Fault messages