Multi-Tech Systems MT2834ZDX ユーザーズマニュアル

ページ / 34
Chapter 3 – AT Commands, S-Registers, and Results Codes 
Multi-Tech Systems, Inc. MT2834ZDX User's Guide 
17
 
 
 
Command:  
%%%AT<CR>    Remote Configuration Escape Sequence 
Values:  
n/a 
Description:  
Initiates remote configuration mode while online with remote modem. The remote configuration 
escape character (%) is defined in register S13. 
 
Command:  
+++AT<CR>     Escape Code 
Values:  
n/a 
Description:  
Puts modem in command mode (and optionally issues a command) while remaining on line. 
 Enter 
+++AT, up to ten command characters (or as defined by S34), and a RETURN. Used mostly 
to issue hang-up command: +++ATH<CR>
 
Command:  
<BREAK>AT<CR>    Escape Sequence 
Values:  
n/a 
Description:  
Alternate escape method. Puts modem in command mode while remaining on line. Send a 
<BREAK> signal followed by AT, up to sixty command characters, and a RETURN. You must set 
the modem to %E2 or %E3 before you can use this escape method.