8.  For propane/LP insert, do not place propane/LP supply 
tank(s) inside any structure. Locate propane/LP supply 
tank(s) outdoors. To prevent performance problems, do not 
use propane/LP fuel tank of less than 100 lbs. capacity. 
9.   The installation must conform with local codes or, in 
the absence of local codes, with the National Fuel Gas 
Code, ANSI Z223.l/NFPA54.
10.  This unit complies with ANSI Z21.11 Unvented Heaters 
and also complies with ANSI Z21.60 Decorative Vented 
Appliances for Solid Fuel Burning Fireplaces. State and 
local codes may only allow operation of this appliance in 
a vented configuration. Check your state or local codes. 
For vented operation, see Vented Instructions in this 
manual.
11.  Do not install the heaters in a bathroom or bedroom.
12.  Correct installation of the ceramic fiber logs, proper 
location of the heater, and annual cleaning are neces-
sary to avoid potential problems with sooting. Sooting, 
resulting from improper installation or operation, can 
settle on surfaces outside the fireplace. See log placement 
instructions for proper installation.
IMPORTANT SAFETY INFORMATION
  1.  Due to high temperatures, the appliance should be 
located out of traffic and away from furniture and 
draperies.
  2.  Children and adults should be alerted to the hazard 
of high surface temperature and should stay away to 
avoid burns or clothing ignition.
  3.  Young children should be carefully supervised when 
they are in the same room with the appliance. 
  4.  Do not place clothing or other flammable material on 
or near the appliance. 
  5.  Any safety screen or guard removed for servicing an 
appliance, must be replaced prior to operating the 
heater.
  6.  Installation and repair should be done by a qualified 
service person.
  7.  To prevent malfunction and/or sooting, an unvented 
gas heater should be cleaned before use and at least 
annually by a professional service person. More 
frequent cleaning may be required due to exces-
sive lint from carpeting, bedding materials, etc. It is 
imperative that control compartments, burners and 
circulating air passageways be kept clean.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with head-
aches, dizziness and/or nausea. If you have these signs, the insert may not have been installed properly. Get fresh air at 
once! Have the insert inspected and serviced by a qualified service person. Some people are more affected by carbon 
monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the 
influence of alcohol, and those at high altitudes. 
Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor 
helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no 
odor exists.
Continued on page 4
IMPORTANT
Read these instructions carefully before installing or trying to operate this vent-free gas heater.
WARNING
•  Any change to this heater or its controls can be dangerous.
•  Improper installation or use of the heater can cause serious injury or death from fire, 
burns, explosion or carbon monoxide poisoning.
• Do not allow fans to blow directly into the stove. Avoid any drafts that alter burner 
flame patterns.
• Do not use a blower insert, heat exchanger insert or other accessory, not approved 
for use with this heater where applicable.
INSTALLER
Please leave these instructions with the appliance.
OWNER
Please retain these instructions for future reference.