Multiquip dca150usj2 ユーザーズマニュアル

ページ / 102
page 18 — DCa150USJ2 60 hz generator • operation anD partS manUal — rev. #0 (08/22/11) 
diagnOstic display
Figure 4. Diagnostic Display
The  diagnostic  display  panel  located  inside  the  control 
box on the generator (Figure 4) is designed  to meet the 
needs  for  instrumentation  and  control  of  electronically 
controlled  engine  communication  using  the  SAEJ1939 
Controller Area Network (CAN).  This diagnostic display is 
a multifunction tool that enables equipment operators to 
view many different engine parameters and service codes.  
The keypad on the diagnostic display panel is a capacitive 
touch sensing system. There are no mechanical switches 
to wear or stick. This keypad (display unit) will operate in 
extreme hot or cold weather conditions.
Other components in the system are microprocessor-based 
components for displaying critical engine data broadcast 
by an electronic engine or transmission’s Engine Control 
Unit (ECU): engine RPM, oil pressure, coolant temperature, 
system voltage, etc., and a combination audible alarm and 
relay unit for warning and shutdown annunciation.
The Engine Control Unit (ECU) used with this generator 
diagnosis  engine  faults  that  arise  with  the  the  engine 
control  system  and  the  engine  itself.  Engine  faults  can 
be determined by viewing the Diagnostic Trouble Codes 
(Active Fault Codes) which are displayed on the Diagnostic 
Display  Panel.  See  the  John  Deere  Engine  Operator’s 
Manual  for  a  complete  listing  of  active  fault  codes  and 
countermeasures.
The following definitions describe the controls and functions 
of the Diagnostic Display Panel (Figure 4).
1. 
menu Button – Press this button to enter or exit menu 
screens.
2. 
left arrow Button – Press this button to scroll through 
the  screen  either  moving  the  parameter  selection 
toward the left or upward.
3. 
right  arrow  Button  –  Press  this  button  to  scroll 
through  the  screen  either  moving  the  parameter 
selection toward the right or downward.
4. 
enter Key Button – Press this button to select the 
parameter that is highlighted on the screen.
5. 
emergency Stop leD – When lit (RED) indicates a 
major fault has occured. This condition will shudown 
the generator.
6. 
Warning leD – When lit (AMBER), indicates a engine 
parameter has exceeded its limits (minor fault). The 
generator will still run in this condition.
7. 
Display Screen – Graphical backlight LCD screen. 
Back  lighting  is  controlled  via  menu  or  external 
dimmer potentiometer. The display can show either a 
single parameter or a quadrant display showing four 
parameters simultaneously.
8. 
Diagnostic Switch – When placed in the ON position, 
will activate the diagnostic display panel.
 
9. 
Can  Diagnostic  Connector  –  Controller  Area 
Network connector. This connector outputs diagnostic 
error codes. Connect a scanner or similar device into 
this connector to read error codes.
Display Parameters
The following are some of the engine and transmission 
parameters displayed on the diagnostic disply panel.
 
„
Engine RPM’s
 
„
Engine Hours
 
„
System Voltage
 
„
% Engine Load at current RPM
 
„
Coolant Temperature
 
„
Oil Pressure
 
„
Fuel Economy
 
„
Current Fuel Consumption
 
„
Throttle Position
 
„
Engine Manifold Air Temperature
 
„
Active Service Codes
 
„
Set Units for Display (English or Metric)
 
„
English Configuration Parameters.