DCa150USJ2 60 hz generator • operation anD partS manUal — rev. #0 (08/22/11) — page 39
Output terMinal panel FaMiliarizatiOn
120 vaC gFCi receptacles
There  are  two  120 VAC,  20  amp  GFCI  (Duplex  Nema 
5-20R) receptacles provided on the output terminal panel. 
These  receptacles  can  be  accessed  in 
any  voltage 
selector switch position. Each receptacle is protected by a 
20 amp circuit breaker. These breakers are located directly 
above the GFCI receptacles. Remember the load output 
(current) of both GFCI receptacles is dependent on the load 
requirements of the U, V, and W output terminal lugs.
Pressing the 
reset button resets the GFCI receptacle after 
being tripped. Pressing the 
test button (See Figure 8) in 
the center of the receptacle will check the GFCI function. 
Both receptacles should be tested at least once a month.
Figure 8. G.F.C.I. Receptacle
twist lock Dual voltage 120/240 vaC receptacles
There are three 120/240V, 50 amp auxiliary twist-lock (CS-
6369)  receptacles  (Figure  9)  provided  on  the  output 
terminal panel. These receptacles can 
only be accessed 
when the voltage selector switch is placed in the 
single-
phase 240/120 position.
Figure 9. 120/240V Twist-Lock Auxiliary 
Receptacles
Each auxiliary receptacle is protected by a 50 amp circuit 
breaker. These  breakers  are  located  directly  above  the 
GFCI receptacles. Remember the load output (current) on 
all three receptacles is dependent on the load requirements 
of the 
output terminal lugs.
Turn the 
voltage regulator control knob (Figure 10) on 
the control panel to obtain the desired voltage. Turning the 
knob clockwise will 
increase the voltage, turning the knob 
counter-clockwise will 
decrease the voltage.
Figure 10. Voltage Regulator Control Knob
removing  the  plastic  Face  plate  (hard Wire 
hookup panel)
The
 Output Terminal Lugs are protected by a plastic 
face plate cover (Figure 11). Un-screw the securing bolts 
and  lift  the  plastic  terminal  cover  to  gain  access  to  the 
terminal enclosure.
After the load wires have been securely attached to the 
terminal lugs, reinstall the plastic face plate.
Figure 11. Plastic Face Plate  
(Output Terminal Lugs)