Multiquip dca150usj2 ユーザーズマニュアル

ページ / 102
DCa150USJ2 60 hz generator • operation anD partS manUal — rev. #0 (08/22/11) — page 55
CheCK oil level
Check the crankcase oil level prior to each use, or when the 
fuel tank is filled. Insufficient oil may cause severe damage 
to the engine. Make sure the generator is level. The oil 
level must be between the two notches on the dipstick as 
shown in Figure 59.
Replacing Oil Filter
 
„
Remove the old oil filter.
 
„
Apply a film of oil to the gasket on the new oil filter.
 
„
Install the new oil filter.
 
„
After the oil cartridge has been replaced, the engine oil 
will drop slightly. Run the engine for a while and check for 
leaks before adding more oil if needed. Clean excessive 
oil from engine.
FlUShing  oUt  raDiator  anD  replaCing 
Coolant
 
„
Open both cocks located at the crankcase side and at 
the lower part of the radiator and drain coolant. Open 
the radiator cap while draining. Remove the overflow 
tank and drain.
 
„
Check hoses for softening and kinks. Check clamps for 
signs of leakage.
 
„
Tighten both cocks and replace the overflow tank.
 
„
Replace with coolant as recommended by the engine 
manufacturer.
 
„
Close radiator cap tightly.
 
„
Flush the radiator by running clean tap water through 
radiator  until  signs  of  rust  and  dirt  are  removed. 
DO 
NOT clean radiator core with any objects, such as a 
screwdriver.
  Warning
Allow  engine  to 
cool when flushing out 
radiator.  Flushing  the  radiator  while  hot 
could cause serious burns from water or 
steam.
raDiator Cleaning 
The radiator (Figure 59) should be sprayed (cleaned) with 
a high pressure washer when excessive amounts of dirt 
and debris have accumulated on the cooling fins or tube. 
When using a high pressure washer, stand at least 5 feet 
(1.5 meters) away from the radiator to prevent damage to 
the fins and tube.
Figure 59. Radiator Cleaning
GENERATOR STORAGE
For  long  term  storage  of  the  generator  the  following  is 
recommended:
 
„
Drain the fuel tank completely. Treat with a fuel stabilizer 
if necessary.
 
„
Completely drain the oil from the crankcase and refill if 
necessary with fresh oil.
 
„
Clean the entire generator, internal and external.
 
„
Cover the generating set and store in a clean, dry place.
 
„
Disconnect the battery.
 
„
Make sure engine coolant is at proper level.
 
„
If generator is mounted on a trailer, jack trailer up and 
place on blocks so tires do not touch the ground or block 
and completely remove the tires.
Maintenance