Multiquip EGC500DD ユーザーズマニュアル

ページ / 4
500kW Containerized
Diesel Generator Set
Cooling System
Exhaust Manifold Type
Dry
Radiator Design
Standard horizontal discharge
Coolant Capacity - Engine
11.6 gal. (44 L)
Coolant Capacity - Engine and Radiator
42 gal. (159 L)
Water Pump Design/Type
Belt Driven, Centrifugal
Coolant Flow
79 gal/min (299 L)
Heat Rejection to Coolant
11535 BTU/min (202.7 kW)
Fan Horsepower
23 hp (17 kW)
Thermostat
188.6 °F (87 °C)
Fuel System
Recommended Fuel
ASTM-D975-No.1 or No. 2-D
Fuel Pump Maximum Lift
 6.0 ft. (1.8 m)
Filter Micron Size - 98% Efficiency
2
Total Fuel Flow
186.1 gal./hr. (704.5 L/Hr.)
Fuel Consumption
Diesel Fuel @ % of Load
gal/hr
L/hr
  25%
10.1
38.2
  50%
18.1
68.5
  75%
26.8
101.4
  100%
37.7
142.7
Lubrication System
Type
Full Pressure System
Oil Filters
2 Spin-on, Full Flow
Oil Pan Capacity
12.2 gal. (46.0 L)
Oil Capacity with Filters
14.3 gal. (54.0 L)
Oil Pressure at Rated Speed
47 - 57 psi (324 - 393 kPa)
Exhaust System
Exhaust Temperature at Rated kW
(Dry Exhaust)
980 
o
F (527 
o
C)
Exhaust Flow at Rated kW
4080 cfm (115.5 m
3
/min)
Silencer Type
Critical
Maximum Allowable Backpressure
41.1 in/wc (10.2 kPa)
Exhaust Outlet Size at hook-up
5.0 in. (127 mm)
Inteligen Digital Genset Controller
■ Large graphic back-lit LCD display 128x64 pixel resolution
■ Automatic and manual starting and stopping
■ Phase sequence supervision
■ Automatic shutdown/alarm function
■ Input frequency 50-60 Hz
■ Parameters adjustable via PC or iG keyboard
■ Predefined and user definable configurations available.
One configuration includes set of inputs/outputs and parameters
■ Adjustable parameters for each configuration
■ 6 LED indicators
■ Push buttons for simple control
■ 4 programmable outputs (out of 20 functions selection)
■ 4 binary configuration inputs
■ Lamp test during start up
■ Real time clock
■ Sealed membrane panel to IP65
■ 180 x 113 mm front panel mounted case
■ Speed measurement from magnetic pickup
■ Oil pressure, Coolant temperature, Battery voltage and Fuel level
measurements
■ Running Hour Meter
■ All Generator metering, kVAr, kW, V1-V3, Hz, I1-I3, kWh, kVAh
■ Generator under/over voltage alarm/shutdown
■ Generator under/over frequency alarm/shutdown
■ Over Current alarm/shutdown
■ Warm up and cooling functions
■ Pre-lubrication function with timers
■ Adjustable crank attempts
■ Data logging
■ Remote communications (RS232/Modbus)
Digital Controller Features
EGC500DD Rev 2