Datalogic Scanning DS8100A ユーザーズマニュアル

ページ / 97
SOFTWARE CONFIGURATION 
3
On Line Operating Mode 
 
 
 Selection 
Figure 54 - On Line Mode
 
This operating mode causes the reader to be connected to an external Presence Sensor 
using EXT TRIG/PS A and 
ts. 
During the active phase of the presence sensor, the DS8100A reader tries to acquire and 
correctly decode the code. 
 case the decoding phase is successful, the barcode characters are transmitted on the 
serial interface. Otherwise, a no read message is sent. 
 
 
Automa ic Op
 
EXT TRIG/PS B inpu
In
t
erating Mode 
 
Figure 55 - Automatic Mode Selection 
 
This operating mode does not require the connection to an external Presence Sensor. 
When working in this mode the reader is continuously scanning. The reading phase is 
activated each time a barcode enters the reading zone. The reader stops reading after an N 
number of scans without a code. 
Barcode characters are transmitted on the serial interface. In case of a failed reading phase 
no message is sent to the host computer. 
 
 
 
43