Gas  line  hook  up  should  be  done  by  your 
supplier or a qualified service person.
Note: Before you proceed, make sure your 
gas supply is turned off.
Use only a 1/2" black iron pipe and appropri-
ate fittings. 
1.  Remove knockout indentation on refrac-
tory or firebrick wall located above refrac-
tory  hearth  floor.  Knockout  indentation 
must be firmly tapped with any solid object 
such as a 1/2" dowel until it is released. 
Remove fragmented portions of refractory 
(see Figure 21).
2.  Remove gas line cover plate located on 
either side of fireplace and pull out insula-
tion  from  gas  line  conduit  sleeve.  Save 
insulation for reuse. Replace screws.
3.  Run a 1/2" black iron gas line into fireplace 
through the rear at gas line conduit sleeve (if 
using a raised platform, add height). Provide 
sufficient gas line into fireplace chamber for 
fitting connection (see Figure 22). 
 
Note: Secure incoming gas line to wood 
framing to provide rigidity for threaded end.
4.  Repack insulation around gas line and into 
sleeve opening. Seal any gaps between 
gas line and refractory knockout hole with 
refractory cement or commercial furnace 
cement, Install the gas appliance or cap-off 
gas line if desired.
  CAUTION:  All  gas  piping 
and connections must be tested 
for  leaks  after  the  installation 
is  completed.  After  ensuring 
that the gas valve is on, apply 
soap  and  water  solution  to  all 
connections and joints. Bubbles 
forming  show  a  leak.  Correct 
all leaks at once. DO NOT USE 
AN  OPEN  FLAME  FOR  LEAK 
TESTING AND DO NOT OPER-
ATE ANY APPLIANCE IF A LEAK 
IS DETECTED. LEAK TESTING 
SHOULD BE DONE BY A QUALI-
FIED SERvICE PERSON.
 WARNING: Do not operate an 
unvented gas log set in this fire-
place with the chimney removed.
Figure 21 - Gas Line Access 
Side 
Firebrick 
Finished 
Side
Brick with 
Access 
Hole
Outside of 
Fireplace
Gas Line 
Conduit
Insulation
Gas 
Conduit 
Cover
1/2" Dowel
Seal 
Opening 
with 
Refractory 
Cement
Outside of 
Fireplace
Gas Line 
Conduit
Repack 
Insulation
Incoming 
1/2" Black 
Iron Pipe
Side 
Firebrick 
Finished 
Side
Provide Enough 
Threaded 
End for Fitting 
Connection
Figure 22 - Gas Line Installation
Remove 
Knockout
OptiOnal gaS line inStallatiOn
If  you  install  a  decorative  gas  appliance 
(vented gas log), the decorative gas appliance 
must comply with the Standard for Decorative 
Gas Appliance  for  Installation  in  Solid  Fuel 
Burning Fireplaces, ANS Z21.60, Z21.84 and 
shall also be installed in accordance with the 
National Fuel Gas Code, ANSI  7223NFPA 
54 latest edition.
  WARNING:  If  the  fireplace 
has been used for wood burning, 
the firebox and chimney must be 
cleaned  of  soot,  creosote  and 
ashes  be  a  qualified  chimney 
cleaner.  Creosote  will  ignite  if 
heavily heated.
  WARNING:  When  using  a 
decorative  vented  gas  log,  the 
damper must be removed or per-
manently locked in the fully open 
position and the glass doors must 
be in the fully open position.