CMS Products 674 ユーザーズマニュアル

ページ / 118
Initial Setup
HotCup Operators’ Guide
6740001
30
November, 2007
V.
ADJUSTMENTS AND MINOR MAINTENANCE
1.
Empty the Bill Stacker
2.
Adjust the Water Valves
Water valves do not usually require adjustment, but in some cases adequate water volume cannot 
be achieved by the throw time setting alone (See “Programming The HotCup” on page 34).  If 
absolutely necessary, adjust the valves in conjunction with setting the factory default timers during 
the Product Configuration programming mode.
a. Using a slotted screwdriver, turn the adjustment screw clockwise to decrease the water flow 
rate.
b. Turn the adjustment screw counterclockwise to increase the water flow rate.
WATER VALVE
ADJUSTMENT
SCREW
WATER
VALVE
+
-
1
2
3
4
5
6
WATER
6
WATER
TANK