ON DIP
3
 
Adjustable Pull High/low, Terminator Resistors for the RS-485 Port 
In some critical environments, you may need to add termination resistors to prevent the reflection 
of serial signals. When using termination resistors, it is important to set the pull high/low resistors 
correctly so that the electrical signal is not corrupted. The UPort uses DIP switches to set the pull 
high/low resistor values for each serial port. 
To set the pull high/low resistors to 150 KΩ, make sure both of the assigned DIP switches are in 
the OFF position. This is the default setting. 
To set the pull high/low resistors to 1 KΩ, make sure both of the assigned DIP switches are in 
the ON position. 
1 2 3 
SW 
Pull High 
Pull Low 
Terminator 
ON 
1KΩ 1KΩ 120 
Ω 
OFF 
150 KΩ 150 
KΩ Disable