Specifications
Rated Power Supply:
AC 100-240V 50/60Hz
Rated Input:
0.60 - 0.30A (100-240V)
Color System:
PAL type color system.
Operating Temperature:
41
°
F-104
°
F (5
°
C to 40
°
C).
Relative Humidity:
Max.80(%)
Altitude:
Max.2000(m)
Dimensions:
300(Width) x 350(Depth) x 88(Height)(mm).
Weight:
5.0kg
Recording System
Digital recording method using WAVELET compression.
Sampling
13.5MHz
Data Compression
WAVELET
Compression Unit
Field
Resolution
684 x 288
Recording Device
250GB HDD
Video Input:
9 Input BNC-Connector:
1.0 V(p-p), 75 ohms.
Monitor Output:
S-Connector:
Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.3 V(p-p), 75 ohms.
C-Signal: 0.3 V(p-p), 75 ohms.
2 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
RCA-Pinplug: 1.0 V(p-p), 75 ohms.
Throughout Output:
Throughout Output:
9 Output BNC-Connector:
1.0 V(p-p), 75 ohms.
Audio Input:
RCA-Pinplug: 308 mV(rms), 50 kohms.
Audio Output:
2 Output RCA-Pinplug: 308 mV(rms), 1 kohms.
Microphone Input:
Ø
3.5mm minijack:
0.346 mV(rms), 600 ohms.
Timer Program:
8 programs-Daily start and stop time for one week x 3set.
Memory Backup:
Lasts for more than 1 month.
CONNECTORS
ALARM IN(1-9) Input:
ALARM IN(1-9) Input:
Terminal for starting alarm recording.
CLOCK ADJ Input:
Terminal for adjusting clock.
REC Input:
Terminal for start recording.
EMERGENCY Input:
Terminal for start emergency recording.
GND:
Terminal for ground.
MODE OUT(1-5) Output:
Terminal for indication of recording selected mode.
DC 12V OUT Output:
Terminal for DC 12V OUT. Max. Drive current 350mA DC. ( 350mA : 11.5 V typ
±
1.5 V )
CALL OUT/CALL OUT GND:
Terminal for external warning device.
Rating:
MODE OUT(1-5)
MODE OUT(1-5)
Active:
“Low” Level.
Max. Drive current 7mA DC.
Non active:
Open.
Max. Voltage +24V DC.
ALARM IN / CLOCK ADJ /
Active:
When terminals are short-circuited
REC/EMERGENCY
or “Low” Level voltage is applied.
Non active:
Open.
CALL OUT /
Active:
ON.
Max. Drive current 7mA DC.
CALL OUT GND
Non active:
Open.
Max. Voltage +24V DC.
RS-232C
RS-232C (D-SUB 9pin) connector for connection with personal computer.
ETHERNET Connector form: RJ-45
Physical interface: 10BASE-T
Physical interface: 10BASE-T
Accessories
AC power cord (for U.K / for the Continent)
AC power cord (for U.K / for the Continent)
2
COMPACT FLASH slot cover (mounted on unit)
1
Compact Flash Card recording format
Original format (FSM2)
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
Design and specifications are subject to change without notice.