Oregon rm600a ユーザーズマニュアル

ページ / 2
EN
Advanced Weather Station 
with USB upload 
Model: RMS600 / RM600A
USER MANUAL
OVERVIEW
FRONT VIEW (FIG. 1)
1
13
14
15
16
17
18
19
20
21
22
23
2
3
4
5
6
7
8
9
10
11
12
1. 
 Outdoor remote sensor battery low
2.  Indicate outdoor channel selected
3. 
Remote sensor reception icon
4.  Moon Phase
5.  Next 12 hour weather forecast / pressure trend
6.  Indoor temperature;  temperature trend
7.  Radio controlled clock reception icon
8. 
 : Indicate AM / PM (RMS600A only)
9. 
 Main unit battery low
10. Ice alert LED indicator
11. MODE: Change settings / display
12. 
  increase  value  of  the  setting;  enable  radio  control 
clock;  select  from  3  outdoor  channels;  scroll  through 
moon phase
13. LIGHT: Activate backlight
14. Outdoor temperature; temperature trend
15. Outdoor humidity and trend
16. Weather  Warning  Message  (HEAT,  WIND,  STORM, 
FROST, FOG)
17. Indoor humidity and trend
18. USB status indicator
19. Time  Zone  indicator  (RMS600A  only):  (P)  Pacific,  (M) 
Mountain, (C) Central , (E) Eastern
20. Clock / calendar display
21. MEM: Change temperature / humidity display (Current, 
Max / Min); clear Max / Min record
22. USB socket
23. 
 decrease value of the setting; disable radio control 
clock; scroll through moon phase
BACK VIEW (FIG 2)
1
2
3
4
1.  °C / °F: Select temperature unit
2.  RESET: Reset unit to default settings
3.  EU / UK: Select the nearest radio signal (RMS600 only)
4.  Battery compartment
REMOTE SENSOR (FIG 3)
1
2
3
4
5
1.  LED status indicator
2.  Wall mount hole
3.  Battery compartment
4.  RESET: Reset unit to default settings
5.  CHANNEL switch
GETTING STARTED
REMOTE SENSOR SET UP
The remote sensor can collect data from up to 3 channels. 
To set up the remote sensor:
1.  Slide open the battery door.
2.  Slide channel switch to select a channel (1, 2, 3).  Ensure 
you use a different channel for each sensor.
3.  Insert  the  battery,  matching  the  polarities  (+  /  -).    See 
FIG 3.
4.  Press RESET after each battery change.
5.  Close the battery door.
NOTE Install battery in the remote sensor before the main 
unit.
6.  Initiate a sensor search on the main unit to start receiving 
temperature / humidity data from the sensor.
          
7.  Secure the sensor in the desired location using the wall 
mount hole.
NOTE Use alkaline batteries for longer usage and consumer 
grade lithium batteries in temperatures below freezing.
MAIN UNIT SET UP
1.  Remove the battery compartment.
2.  Insert the batteries, matching the polarities (see FIG 2).
3.  Press RESET after each battery change.
NOTE  Batteries  should  not  be  exposed  to  excessive  heat 
such as sunshine or fire.
   LOCATION
MEANING
Clock / alarm area
Main unit batteries low
Outdoor sensor area
Sensor batteries low
DATA TRANSMISSION
To search for a sensor: 
Press and hold 
 + MODE.
The  remote  sensor  reception  icon  will  show  the 
following status:
ICON
DESCRIPTION
Main unit is searching for sensor(s).
A channel has been found.
The sensor cannot be found. 
TIP The transmission range may vary depending on many 
factors. You may need to experiment with various locations 
to get the best results.
CLOCK 
CLOCK RECEPTION
This  product  is  designed  to  synchronize  its  clock 
automatically with a clock signal.
RMS600:
Slide EU / UK to select the signal received.
•  EU:  DCF-77  signal:  within  1500  km  (932  miles)  of 
Frankfurt, Germany.
•  UK:  MSF-60  signal:  within  1500  km  (932  miles)  of 
Anthorn, England.
RMS600A:
WWVB-60  signal:  within  3200  km  (2000  miles)  of  Fort 
Collins, Colorado.
To enable / disable clock signal reception:
Press  and  hold 
  to  enable  or 
  to  disable  clock 
signal reception.
NOTE Reception takes 2-10 minutes. If the signal is weak, 
it  can  take  up  to  24  hours  to  get  a  valid  signal.
 
If  signal 
reception is unsuccessful, place your unit next to a window, 
press and hold 
 to force another signal search.
 
Clock signal reception indicator: 
STRONG SIGNAL
WEAK / NO SIGNAL
MANUALLY SET CLOCK
To set the clock manually, disable the clock signal reception 
first.
1.  Press and hold MODE.
2.  Press 
 or 
 to change the settings. The settings 
order is: time zone, 12/24 hr format, hour, minute, year, 
calendar mode (month – day / day – month), month, day 
and language.
3.  Press MODE to confirm.
RMS600:  Time  zone  sets  the  clock  +/-  23  hours  from  the 
received clock signal time. 
RMS600A: Select the time zone: (P) Pacific, (M) Mountain, 
(C) Central, or (E) Eastern.
NOTE The language options are English (E), German (D), 
French (F), Italian (I), Spanish (S) and Russian (R).
To select clock display mode:
Press MODE to toggle between clock with seconds, clock 
with weekday.
SET UP SOFTWARE (FIRST TIME USE)
The  main  unit  is  capable  of  connecting  to  a  PC  computer 
using  the  USB  connection.    Weather  data  of  temperature 
and humidity readings can be uploaded to the computer by 
connecting the main unit to the computer.
PC system requirements
The minimum system requirements for use of the software 
is:
•   Operating system: Microsoft Windows XP SP2 or  
Vista
•  Processor: Pentium III or 4 (recommended)
•  RAM: Min. 256 MB or 512 MB (recommended)
•  Hard disk free space: Min. 256 MB or 512 MB
 
(recommended)
•  Screen Display Area:1024 x 768 pixels 
(recommended)
WINDOWS XP
To install software:
1.  Run CD software provided.
2.  Setup wizard dialogue box will appear and guide you 
through the installation process.
3.  After  successful  installation,  double  click  on   
 
desktop shortcut.
4.  Click  DISPLAY  in  Oregon  Weather  Station  dialogue 
box.
  WINDOWS VISTA
To Disable User Access Control (UAC):
1.  From  the  desktop,  My  Computer  >  Control  Panel  > 
User  Accounts  and  Family  Safety  >  Change  your 
Windows password
 > Turn User Account Control On 
or Off
.
2.  Deselect the UAC option by un-ticking.
3.  Follow steps 1-4 from above section.
DISABLE SLEEP MODE
To allow for continuous update of data, ensure Sleep Mode 
on computer is disabled.
 TO DISABLE SLEEP MODE ON COMPUTER
 (WINDOWS XP )
1.   Right click on Desktop.
2.   Choose “Properties”.
3.   Click  on  “Screen  Saver”  Tab  in  the  Display  Properties 
window.
4.   Click on “Power” located at the bottom half of window.
5.   A new window “Power Options Properties” will open.
6.   Under “System standby” option, choose “Never” in drop 
down menu.
7.   Click “Apply” and then click “OK”.
8.   Previous window will return.  Click “OK” to confirm and exit.
TO DISABLE SLEEP MODE ON COMPUTER
(WINDOWS VISTA)
1.   Right click on Desktop.
2.  Choose “Personalize”.
3.   Click  on  “Screen  Saver”  Tab  in  the  Display  Properties 
window.
4.  Click on “Change Power Settings” located at the bottom 
half of window.
5.   Select  “High  Performance”  and  click  “Change  plan 
settings”.
6.  Click “Change advanced power settings”.
7.  Click “Sleep” and click “Hibernate after”.
8.   Click “Setting” and set “0” minutes.
9.   Click “Apply” and then “OK”.
CONNECTION TO PC
To upload the weather data to the computer:
1.  Plug one end of the USB cable into the USB port and the 
other end into the computer. 
2.  If data upload is completed, the display will show
     “
”.
NOTE The USB is only used for uploading weather data. It 
cannot be used for charging battery power.
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather 
within a 30-50 km (19-31 mile) radius with a 75% accuracy.
ICON
DESCRIPTION
Sunny
   
Partially Cloudy
Cloudy
    
Rainy
   
Snowy
WEATHER WARNING MESSAGE
The  weather  warning  messages  provide  indications  of 
probable circumstances that may arise based on the weather 
station’s  calculations.  The  meanings  for  the  warnings  are 
illustrated below:  
  Warning
Meaning
Risk of high temperatures
   
Risk of fast wind speeds
Risk of a storm
Risk of foggy conditions
    
Risk of icy conditions
TEMPERATURE AND HUMIDITY
To toggle temperature unit:
Press °C / °F.
To auto-scan channels:
Press  and  hold 
  +  MEM  to  display  each  channel’s 
recorded data sequentially. 
To select channel, press 
.
To  toggle  between  current,  minimum  and  maximum 
temperature/ humidity record of a selected channel:
Press MEM.
To clear the temperature / humidity record displayed:
Press and hold MEM.
ICE ALERT (CHANNEL 1 ONLY)
If the temperature falls between 3°C to -2 °C (37°F to 28°F), 
the green ice alert LED indicator will flash continuously, and 
will stop flashing once the temperature is out of this range. 
WEATHER TRENDS
The  temperature,  humidity  and  pressure  trend  icons  are 
based on recent sensor readings. 
RISE
STEADY
FALL
MOON PHASE
In moon phase mode, press 
 or  
 to scan through 
the years (2001 to 2099). 
New Moon
 Full Moon
Waxing 
Crescent
Waning Gibbous
First quarter
Last quarter
Waxing Gibbous  
Waning 
Crescent
BACKLIGHT
Press LIGHT to activate LED backlight for 5 seconds.
RESET
Press RESET to return to the default settings.
SPECIFICATIONS
TYPE
DESCRIPTION
MAIN UNIT
L x W x H
82 x 60 x 210 mm 
(3.23 x 2.36 x 8.27 in)
Weight
260 g (9.17 oz) 
without battery
Signal frequency 
433 MHz
Temperature range
-5°C to 50°C  (23°F to 122°F)
Temperature 
resolution
0.1°C (0.2°F)
Ice alert 
temperature range
3°C to -2°C
(37°F to 28°F)
Humidity range
25% - 95%
Humidity resolution
1%
Power
3 x UM-3 (AA) 1.5 V batteries
REMOTE UNIT (THGN132N)
L x W x H
50 x 22 x 96 mm (1.9 x 0.9 x 3.8 in)
Weight
62 g (2.2 ounces) without battery
Signal frequency 
433 MHz
Number of channel
3
Transmission range
30 m (98 ft) unobstructed
Temperature range
-20°C to 60°C  (-4°F to 140°F)
Humidity range
25% - 95%
Humidity resolution
1%
Power
1 x UM-3 (AA) 1.5 V battery
PRECAUTIONS
•  Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.
•  Do not cover the ventilation holes with any items such as 
newspapers, curtains etc.
•  Do not immerse the unit in water. If you spill liquid over 
it, dry it immediately with a soft, lint-free cloth.
•  Do  not  clean  the  unit  with  abrasive  or  corrosive 
materials. 
•  Do not tamper with the unit’s internal components. This 
invalidates the warranty.
•  Only  use  fresh  batteries.  Do  not  mix  new  and  old 
batteries.
•  Images shown in this manual may differ from the actual 
display.
•  When  disposing  of  this  product,  ensure  it  is  collected 
separately  for  special  treatment  and  not  as  normal 
household waste.
•  Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  finish  for  which  Oregon 
Scientific  will  not  be  responsible.  Consult  the  furniture 
manufacturer's care instructions for information.
•  The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.
•  Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.  Collection of such waste separately for special 
treatment is necessary.
•  Please  note  that  some  units  are  equipped  with  a 
battery  safety  strip.  Remove  the  strip  from  the  battery 
compartment before first use.
NOTE The technical specifications for this product and the 
contents of the user manual are subject to change without 
notice.
NOTE Features and accessories will not be available in all 
countries.  For more information, please contact your local 
retailer.
ABOUT OREGON SCIENTIFIC
Visit  our  website  (www.oregonscientific.com)  to  learn 
more about Oregon Scientific products. If you’re in the US 
and  would  like  to  contact  our  Customer  Care  department 
directly, please visit: 
www2.oregonscientific.com/service/support.asp 
For international inquiries, please visit: 
www2.oregonscientific.com/about/international.asp
EU-DECLARATION OF CONFORMITY
Hereby,  Oregon  Scientific,  declares  that  this  Advanced 
Weather  Station  with  USB  upload  (model:  RMS600  / 
RMS600A) is in compliance with the essential requirements 
and  other  relevant  provisions  of  Directive  1999/5/EC.  A 
copy of the signed and dated Declaration of Conformity is 
available  on  request  via  our  Oregon  Scientific  Customer 
Service.
COUNTRIES RTTE APPROVED COMPLIED
All EU countries, Switzerland   CH
                                              and Norway    N
FCC STATEMENT
This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.
WARNING  Changes  or  modifications  not  expressly 
approved by the party responsible for compliance could void 
the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide 
reasonable  protection  against  harmful  interference  in  a 
residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency energy and, if not installed and used in accordance 
with  the  instructions,  may  cause  harmful  interference  to 
radio  communications.  However,  there  is  no  guarantee 
that  interference  will  not  occur  in  a  particular  installation. 
If this equipment does cause harmful interference to radio 
or television reception, which can be determined by turning 
the  equipment  off  and  on,  the  user  is  encouraged  to  try 
to correct the interference by one or more of the following 
measures:
•  Reorient or relocate the receiving antenna.
•  Increase  the  separation  between  the  equipment  and 
receiver.
•  Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.
•  Consult  the  dealer  or  an  experienced  radio  /  TV 
technician for help.
DECLARATION OF CONFORMITY
The  following  information  is  not  to  be  used  as  contact  for 
support or sales. Please call our customer service number 
(listed  on  our  website  at  www.oregonscientific.com,  or  on 
the warranty card for this product) for all inquiries instead.
We
Name: 
 
Oregon Scientific, Inc.
Address:   
19861 SW 95
th
 Ave.,Tualatin,
 
 
 
Oregon 97062 USA
Telephone No.: 
1-800-853-8883
declare that the product 
Product No.: 
RMS600 / RMS600A
Product Name: 
Advanced Weather Station with  
 
 
USB upload
Manufacturer: 
IDT Technology Limited
Address:   
Block C, 9/F, Kaiser Estate,
 
      
 
Phase 1,41 Man Yue St.,    
 
 
Hung Hom, Kowloon, 
 
 
 
Hong Kong
is in conformity with Part 15 of the FCC Rules.  Operation is 
subject to the following two conditions: 1) This device may 
not cause harmful interference. 2) This device must accept 
any  interference  received,  including  interference  that  may 
cause undesired operation.
FR
Station météo à connexion PC 
Modèle : RMS600 / RMS600A 
MANUEL DE  L’UTILISATEUR
VUE D’ENSEMBLE
FACE AVANT (FIG 1)
1
13
14
15
16
17
18
19
20
21
22
23
2
3
4
5
6
7
8
9
10
11
12
1. 
 La pile de la sonde sans fil est faible
2. 
 Indique que le canal extérieur est sélectionné
3. 
Icône de réception de la sonde sans fil
4.  Phases lunaires
5.  Prévision  météo  /  variation  de  pression  des  12 
prochaines heures
6.  Température intérieure ; variation de température
7.  Icône de réception de l’horloge radio-pilotée
8. 
 : Indique AM / PM (modèle RMS600A)
9. 
 Piles faibles (Appareil principal)
10. Indicateur LED d’alerte de gel
11. MODE : modifie les réglages / l’affichage 
12. 
  augmente  la  valeur  d’un  réglage  ;  active  l’horloge 
radio-pilotée  ;  sélection  des  3  canaux  extérieurs  ; 
défilement des phases lunaires  
13. LIGHT : Permet d’activer le rétro-éclairage 
14. Température extérieure ; variation de température
15. Humidité extérieure et variation
16. Message  d’alerte  météorologique  (CHAUD,  VENT, 
TEMPETE, GEL, BROUILLARD) 
17. Humidité intérieure et variation 
18. Indicateur du statut USB 
19. Indicateur du fuseau horaire (modèle RMS600A) Fuseau 
horaire  Pacifique  (P),  des  Montagnes  (M),  Central  (C) 
ou de la côte  Est (E)
20. Affichage horloge / calendrier 
21. MEM : Modifie l’affichage de la température / humidité 
(actuelle, Max/Min), efface les relevés Max/Min
22. Port USB
23. 
  diminue la valeur d’un réglage ; désactive l’horloge 
radio-pilotée ; défilement des phases lunaires 
FACE ARRIÈRE  ( FIG 2)
1
2
3
4
1.  °C / °F: Permet de sélectionner l’unité de mesure de la 
température
2.  RESET: Réinitialise l’appareil aux réglages par défaut
3.  EU  /  UK:  Sélectionne  le  signal  radio  le  plus  proche 
(modèle RMS600 uniquement)
4.  Compartiment des piles 
SONDE SANS FIL (FIG 3)
1
 
2
3
4
5
1.  Indicateur LED
2.  Trou de fixation murale
3.  Compartiment des piles
4.  RESET: Réinitialise l’appareil aux réglages par défaut
5.  Bouton CHANNEL (canal) 
POUR COMMENCER
INSTALLATION DE LA SONDE SANS FIL 
La sonde sans fil est à même de collecter les données sur 
3 canaux.
Installation de la sonde sans fil:
1.  Ouvrez le couvercle du compartiment des piles.
2.  Positionnez l’interrupteur de canal pour sélectionner un 
canal (1, 2, 3). Assurez-vous d’utiliser un canal différent 
pour chaque sonde.
3.  Insérez la pile, en respectant les polarités (+/-). Voir FIG 
3.
4.  Appuyer  sur  RESET  après  chaque  changement  de 
piles.
5.  Fermez le couvercle du compartiment des piles.
REMARQUE Insérez la pile de la sonde sans fil avant celles 
de l’appareil principal.
6.  Lancez  une  recherche  de  sonde  à  partir  de  l’appareil 
principal  pour  que  la  sonde  transmette  les  données 
relatives à la température / à l’humidité.
7.  Sécurisez la sonde à l’emplacement choisi, en utilisant 
la fixation murale.
REMARQUE  Utiliser  des  piles  alcalines  pour  une  plus 
grande  longévité  et  des  piles  au  lithium  en  vente  aux 
particuliers pour des températures en dessous de 0 c.
INSTALLATION DE L’APPAREIL PRINCIPAL
1.  Retirez le couvercle du compartiment des piles.
2.  Insérez les piles, en respectant les polarités 
 
(voir FIG 2).
3.  Appuyez  sur  RESET  (Réinitialiser)  après  chaque 
changement de piles.
REMARQUE  N’exposez  pas  les  piles  à  une  chaleur 
excessive comme les rayons du soleil et le feu. 
 
  EMPLACEMENT
SIGNIFICATION
Zone Horloge / alarme
Piles  faibles  (Appareil 
principal)
Zone  de  la  sonde 
extérieure 
Piles 
du 
capteur 
faibles
TRANSMISSION DES DONNEES
Recherche d’un capteur : 
Appuyez et maintenez la touche  
 + MODE.
L’icône de réception de la sonde sans fil indiquera le statut 
suivant : 
ICONE
DESCRIPTION
L’appareil  principal  est  à  la 
recherche de la/des sonde(s).
Un canal a été trouvé.
La sonde est introuvable. 
ASTUCE  La  distance  de  transmission  peut  varier  en 
fonction  de  plusieurs  facteurs.  Vous  pouvez  essayer 
plusieurs  emplacements,  afin  d’obtenir  les  meilleurs 
résultats possibles.
HORLOGE 
RÉCEPTION DE L’HORLOGE
Ce  produit  est  conçu  pour  synchroniser  automatiquement 
l’horloge avec le signal radio.
RMS600 :
Positionnez l’encoche EU / UK pour sélectionner le signal 
à recevoir.
•  EU : Signal DCF-77 : dans un rayon de 1500 Km (932 
miles) depuis Frankfort, Allemagne.
•  UK : Signal MSF-60 : dans un rayon de 1500 Km (932 
miles) depuis Anthorn, Angleterre.
RMS600A :
Signal WWVB-60 :  dans un rayon de 3200 km (2000 miles) 
de Fort Collins, Colorado.
Pour  activer  /  désactiver  le  signal  de  réception  de 
l’horloge :
Maintenez le bouton  
 pour activer, ou le bouton 
 
pour désactiver la réception du signal.
REMARQUE La réception prend entre 2 et 10 minutes. Si le 
signal est faible, 24 heures peuvent être nécessaires pour 
obtenir un signal valide. Si la réception échoue, positionnez 
votre  appareil  à  proximité  d’une  fenêtre,  appuyez  et 
maintenez 
 pour forcer la recherche du signal. 
 Indicateur de réception du signal de l’Horloge : 
SIGNAL FORT
SIGNAL FAIBLE / 
AUCUN SIGNAL
REGLER MANUELLEMENT L’HORLOGE
Pour  régler  manuellement  l’horloge,  vous  devez,  tout 
d’abord, désactiver la réception du signal.
1.  Appuyez et maintenez la touche  MODE.
2.  Appuyez sur 
 ou 
 pour modifier les réglages. 
Les réglages s’effectuent dans l’ordre suivant : Fuseau 
horaire,  format  12/24  heures,  heure,  minutes,  année, 
mode calendrier (format mois-jour / jour-mois) mois, jour 
et langue.
3.  Appuyez sur MODE pour confirmer.
RMS600 : La fonction de fuseau horaire règle l’horloge à +/- 
23 heures de l’heure du signal reçu.  Si vous avez désactivé 
la  réception  du  signal  de  l’horloge,  ne  configurez  pas  de 
valeur pour le fuseau horaire.
RMS600A : Sélectionnez le fuseau horaire :  Heure Pacifique 
(P), des Montagnes (M), Centrale (C) ou de la Côte Est (E).
REMARQUE  Les  langues  disponibles  sont  l’anglais  (E), 
l’allemand (D), le français (F), l’italien (I) , l’espagnol (S) et 
le russe (R).
Pour sélectionner le mode d’affichage de l’horloge :
Appuyez  sur  MODE  pour  alterner  entre  l’horloge  avec 
les secondes, l’horloge avec les jours de la semaine et le 
calendrier. 
INSTALLATION DU LOGICIEL  (PREMIERE UTILISATION) 
L’appareil  principal  peut  être  connectée  à  un  ordinateur  à 
l’aide d’une connexion USB.  Vous pouvez télécharger les 
prévisions de température et d’humidité sur votre ordinateur 
en connectant l’appareil principal à votre PC.