Q-Logic 8200 ユーザーズマニュアル

ページ / 170
2–Configuring NIC
NIC TroubleShooting/Diagnostics
SN0054671-00  B
2-85
For example:
qaucli -nic -testlink
=== Link Test for 1. CNA Port Index ===
Function is not supported by this hardware/driver/api stack
=== Link Test for 2. CNA Port Index ===
Function is not supported by this hardware/driver/api stack
=== Link Test for 3. CNA Port Index ===
Function is not supported by this hardware/driver/api stack
=== Link Test for 4. CNA Port Index ===
Function is not supported by this hardware/driver/api stack
=== Link Test for 5. CNA Port Index ===
Link Test Starts...
Test Status: Passed (Passed=1, Failed=0, ErrorCode=0)
Register Test Results:
Status=Passed
Passed=1,
Failed=0, ErrorCode=0
=== Link Test for 6. CNA Port Index ===
Link Test Starts...
Test Status: Passed (Passed=1, Failed=0, ErrorCode=0)
Register Test Results:
Status=Passed
Passed=1, Failed=0, ErrorCode=0
Hardware 
(Continued)
HW_EPG_QREAD_TOUT 
EPG read queue timeout
HW_EPG_QWRITE_TOUT 
EPG write queue timeout 
HW_EPG_CQ_W_FULL 
EPG completion queue write full 
HW_EPG_MSG_CHKSM Egress 
packet generator (EPG) mes-
sage checksum error 
HW_EPG_MTLQ_TOUT
EPG MTL queue fetch timeout 
HW_PEG0 
PEG 0 is not used 
HW_PEG1 
PEG 1 is not used 
HW_PEG2 
PEG 2 is not used 
HW_PEG3 
PEG 3 is not used 
HW_ERRCNT 
Hardware error count
Table 2-16. Windows Diagnostic Test Messages  (Continued)
Test
Error Message
Description