Hitachi L100 ユーザーズマニュアル
![Hitachi](https://files.manualsbrain.com/attachments/318a30c9d46cae1a03ff29c8e1a8ce7b06c25f29/common/fit/150/50/c3659964771301ddbc1d53d08b2407adc4af72464bc0f65ffa4212552d47/brand_logo.png)
“C” Group: Intelligent Terminal Functions
Configur
ing
Dr
iv
e P
a
ra
m
e
ters
3–38
Analog Function Summary Table – This table shows all three functions for the analog
output [FM] (frequency meter) terminal. Detailed descriptions, related parameters and
settings, and example wiring diagrams are in
output [FM] (frequency meter) terminal. Detailed descriptions, related parameters and
settings, and example wiring diagrams are in
.
Analog Function Summary Table
Option
Code
Function Name
Description
00
Analog Frequency
Monitor
Monitor
PWM (pulse-width-modulated) voltage output that has a
duty cycle proportional to the inverter output frequency
duty cycle proportional to the inverter output frequency
01
Analog Current Output
Monitor
Monitor
PWM (pulse-width-modulated) voltage output that has a
duty cycle proportional to the inverter output current to the
motor. It reaches 100% duty cycle when the output
reaches 200% of the rated inverter current.
duty cycle proportional to the inverter output current to the
motor. It reaches 100% duty cycle when the output
reaches 200% of the rated inverter current.
02
Digital Frequency
Output Monitor
Output Monitor
FM (frequency-modulated) voltage output with a constant
50% duty cycle. Its frequency = inverter output frequency.
50% duty cycle. Its frequency = inverter output frequency.