3.4.4 Shadin 200 0 (Cat. 2 ID 10)
Air Data Type 10 (Shadin 2000 or equivalent) is a low speed, digital ARINC 429 signal having the air data labels
203, 204, 206, and 212. Total Air Temperature is from a dedicated (EGPWS) 500-ohm probe using +5 volt
excitation from the MK VI/MK VIII EGPWC.
203, 204, 206, and 212. Total Air Temperature is from a dedicated (EGPWS) 500-ohm probe using +5 volt
excitation from the MK VI/MK VIII EGPWC.
39
38
A
B
J2
ARINC 429 Air Data
ARINC 429 Bus - Hi
ARINC 429 Bus - Lo
EGPWS MK VI / MK VIII
A
B
ARINC 429 Low Speed
Air Data Bus
(+)
(-)
Temp. Input
Chassis Ground
+5V Excitation
500 ohm
Temperature
Probe
25
63
44
53
J1
Shadin2000.vsd
Cat 2
Bus 1
Bus 2
Vendor PN
ID
A
B
A
B
962830-1,2,3
10
J2-7
J2-8
962830A-1,2,3
962830A-X-S-4
962830A-X-S-5
962830A-X-S-4
962830A-X-S-5
10
J1-40
J1-22
NOTE:
The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. Please
contact the manufacturer’s customer service to confirm your installation.