Advanced Setup Menu 
To get to the Advanced Setup Menu, press and hold the ESC button for three seconds. 
The Advanced Setup menu includes options for the more advanced user.  Normally these 
functions are not used in the daily operation of the QD-MultiDrive duplicator.  If you have any 
questions about using these functions, please contact the Microboards technical support 
department.
 
UnderRun Protect 
The UnderRun Protect feature allows the recorder to use Burn Proof during recording.  This 
setting defaults to ON and should remain on.  This feature protects against making “coasters” 
or bad discs.  Again, this setting should always remain ON. 
Overburn 
The default setting for this feature is OFF.  Overburn can be used with certain CD recorders, 
to allow more data to be writing to the disc.  This feature is not supported by the QD-
MultiDrive duplicator.
 
Read Error Skip 
The Read Error Skip feature is used if you wish to ignore read errors during duplication.  The 
default setting is OFF and it is highly recommended that this setting is not changed.  If it is 
turned ON, there is the possibility of copying a disc that is not the same as the master. 
Burn-in 
The Burn-in function is used to test the operation of the QD-MultiDrive duplicator and is for 
service purposes only.  This function should only be used if directly by Microboards Technical 
Support.
 
Update Firmware 
The Update Firmware feature is used to update the controller firmware.   
1.  To update the firmware: Place the firmware CD into the TOP reader drive.
 
2.  Press the ENT button
 
3.  The display will show:
 
 
 
 
 
4.  Press the ENT button to complete the firmware update. 
5.  The duplicator will reboot automatically after installing the new firmware. 
Compare Firmware 
The Compare Firmware function is used to compare the firmware installed on the controller 
with the firmware on the CD.   
H/W Diagnostic 
Hardware Diagnostics runs a number of tests on the controller.  Normally this function is used 
by service personnel.
 
Load Default 
The Load Default feature will set all the values back to the factory default settings. 
Update F/W      X.12Y 