Search and Close Call Options
On
  The scanner automatically applies repeater reverse to 
detected transmissions. If the scanner detects the trans-
mission on the output frequency, it beeps and 
displays Repeater Found and remains on the output 
frequency until transmissions end. If it does not detect a 
transmission on the output frequency, it remains on the 
original frequency.
Off
   The scanner does not try to find the output frequency.
Setting the Maximum Auto Store 
Value
 
   
 Srch/CloCall Opt 
 
E
   
Max Auto Store 
 
E
 
This value sets how many hits the scanner will automati-
cally store when it is in either Search and Store or Close 
Call Auto Store mode.
Use the number keys to enter a value from 1 - 256, then 
press E.
When the scanner reaches the maximum number of hits 
you set, it stops the auto-store operation.
Setting the Modulation Type
 
   
 Srch/CloCall Opt 
 
E
   
Set Modulation 
 
E
 
This setting controls the modulation type used for quick 
search and Close Call operations. Select your setting, then 
press E.
Auto
  Uses the default setting for the current frequency 
(see the table at the front of the manual)
AM 
  Uses AM (amplitude modulation)
FM
   Uses FM (frequency modulation)
NFM
  Uses narrowband FM
Menu
Menu