Chamberlain WD962KPEV ユーザーズマニュアル

ページ / 48
24
DOOR TRACK INSTALLATION
The safety reversing sensors can be attached to the door track, the wall, or the fl oor. The sensors should be no more than 6 inches (15 cm) above the fl oor. If the door track will not support 
the sensor bracket a wall installation is recommended. Choose one of the following installations.
HARDWARE
H17 (2)
Carriage Bolt
1/4"-20x1/2" 
H18 (2)
Wing Nut
1/4"-20 
1.2A  
Slide the carriage bolt (H17) into 
the slot on each sensor.
1.3A  
Insert the bolt through the hole in 
the sensor bracket and attach with 
the wing nut (H18). The lenses on 
both sensors should point toward 
each other. Make sure the lens 
is not obstructed by the sensor 
bracket.
1.1A  
Slide the curved arms of the 
sensor bracket around the edge 
of the door track. Snap into place 
so that the sensor bracket is fl ush 
against the track. 
Install the Safety Reversing Sensors
1
H17
no more 
than 6 inches 
(15 cm)
H18
Option A
Inside
Garage
Wa
ll
Ins
de
Garage
Wall
Wa
ll
(not provided)
(not provided)
WALL INSTALLATION
1.1B  
Position the sensor bracket against 
the wall with the curved arms 
facing the door. Make sure there is 
enough clearance for the beam to 
be unobstructed. Mark holes.
1.3B  
Slide the carriage bolt (H17) into 
the slot on each sensor.
1.4B  
Insert the bolt through the hole in 
the sensor bracket and attach with 
the wing nut (H18). The lenses on 
both sensors should point toward 
each other. Make sure the lens 
is not obstructed by the sensor 
bracket.
1.2B  
Drill 3/16 inch pilot holes for 
each sensor bracket and attach 
the sensor brackets to the wall 
using lag screws (not provided).
If additional clearance is needed an extension bracket (not provided) or wood blocks can be used. Make sure that each bracket will have the same amount of clearance so they will align 
correctly.
H17
H18
Lens
Option B
Install the Protector System
®
no more 
than 6 inches 
(15 cm)