Honeywell MS4980 ユーザーズマニュアル

ページ / 48
 
 
7
I
NSTALLATION
 
 
Keyboard Wedge 
 
1.  Turn off the host device. 
 
2.  Plug the 15-pin socket end 
of the
 
cable into the 15-pin D-Type 
connector on the MS4980 (see page 4).  
 
 
3.  Disconnect the keyboard from the host 
device. 
 
4.  Connect the “Y” ends of the 
communication cable to the keyboard 
and keyboard port on the host device.  If 
necessary, use the male/female adapter 
cable supplied with the scanner for 
proper connections. 
 
5.  Plug the power supply into the power 
jack on the PowerLink cable.
 
 
 
Check the AC input requirements 
of the power supply to verify the 
voltage matches the AC outlet.  
The outlet must be located near 
the equipment and be easily 
accessible. 
 
6.  Connect AC power to the transformer. 
 
7.  The MS4980 will start to initialize.  The white and blue LED will alternately 
fade on and off for approximately three seconds.  When the scanner has 
finished initializing, the unit will flash the white LED three times while 
simultaneously beeping three times.  The low intensity blue LED will remain 
turned on. 
 
8.  Turn on the host device.  The scanner will automatically reboot after host 
device is turned on. 
 
Plugging the scanner into a port on the host system does not guarantee 
that scanned information will be communicated properly to the host 
system.  Please refer to the MetroSelect Single-Line Configuration 
Guide or MetroSet2’s help files for instructions on changing the 
scanner’s factory default configuration. The scanner and host system 
must use the same communication protocols.    
 
See caution on page 5. 
  
Figure 7.