Operation 
Instructions
DESCRIPTION
The MCT-3 MegaCode
®
 digital transmitter is a wireless radio control 
designed for use with automatic garage and gate operators.
Each of the three transmitter buttons will send a unique code when 
pressed. One button can be used to activate the individual’s garage 
door opener, a second button can operate an access gate, a third 
button  can  activate  an  additional  garage  door  operator  or  most 
Linear 318 MHz MegaCode
®
 wireless receivers.
MegaCode
®
  transmitters  and  receivers  do  not  contain  a  typical 
“coding  switch”.  Each  transmitter  is  permanently  coded  at  the 
factory. The  receiver  is  programmed  by “learning”  a  transmitter’s 
unique  digital  code.  The  receiver  will  activate  only  from  the 
“memorized” transmitters.
The transmitter is powered by two Type 2032 “coin-cell” batteries. 
They should last 3 years with normal use. The red indicator on the 
face of the transmitter will glow when the unit is activated. If the 
indicator lights dimly, or not at all when transmitting, the batteries 
need to be replaced. To conserve battery life, an internal timer limits 
the transmission duration to 10 seconds if a transmitter button is 
held down.
PROGRAM RECEIVER & TEST TRANSMITTER
Refer  to  the  instructions  provided  with  the  receiver  to  set  it  into 
“learn” mode. With the receiver ready to learn, press the desired 
transmitter  button  to  program  that  button  into  the  receiver’s 
memory. Repeat to program additional buttons for other receivers.
After programming, test the transmitter from various locations. 
Be 
sure the door or gate areas are clear. Activate the transmitter 
and verify that the receiver triggers the operator(s).
VISOR CLIP INSTALLATION
REPLACING THE BATTERY
LINEAR LIMITED WARRANTY
This product is warranted to the consumer against defects in material and workmanship for one year from 
the date of purchase. This warranty applies to first retail buyers of new devices. Warrantor will repair, or at 
its option, replace, any device it finds that requires service under this warranty, and will return the repaired 
or replaced device to the consumer at the warrantor’s cost. For warranty service and shipping instructions 
contact warrantor at the address shown below. Devices must be sent to warrantor for service at owner’s 
expense. The remedies provided by this warranty are exclusive. Implied warranties under state law are to 
the one year period of this written warranty. Some states do not allow limitations on how long an implied 
warranty lasts, so the above limitation may not apply to you. In order to be protected by this warranty, save 
your proof of purchase and send copy with equipment should repair be required. This warranty gives you 
specific legal rights, and you may also have other rights which vary from state to state.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact 
Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless 
signaling. However, there are some limitations which must be observed.
•  For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 
devices. As such, they have limited transmitter power and therefore limited range.
•  A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio 
signals that occur on or near their operating frequencies, regardless of code settings.
•  Changes or modifications to the device may void FCC compliance.
•  Infrequently used radio links should be tested regularly to protect against undetected interference or 
fault.
•  A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor 
or dealer, and these facts should be communicated to the ultimate users.
•  This device complies with FCC Part 15 and Industry Canada Rules and Regulations. Operation is subject 
to the following two conditions: (1) This device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired operation.
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
BE SURE THE DOOR OR
GATE AREA IS CLEAR!
ACTIVATE THE TRANSMTTER
TO TEST THE RECEIVER
AND OPERATOR
THE VISOR CLIP CAN
BE INSTALLED FOR
HORIZONTAL OR
VERTICAL MOUNTING
SLIDE THE VISOR CLIP INTO ONE
OF THE SLOTS ON THE REAR
OF THE TRANSMITTER
1
TWIST DIME IN SLOT
TO OPEN CASE
2
LIFT OFF
THE TOP OF
THE CASE
3
CAREFULLY
REMOVE THE
CIRCUIT BOARD
4
REMOVE OLD BATTERIES
AND DISPOSE OF THEM PROPERLY
5
INSERT TWO NEW
TYPE 2032 BATTERIES
PLUS SIDE UP THEN
REASSEMBLE UNIT
NOTE: THE CIRCUIT BOARD WILL FIT ONLY ONE 
WAY INTO THE CASE. ALIGN THE PLASTIC POST 
IN THE CASE WITH THE HOLE IN THE CIRCUIT BOARD
CLOSE LIMIT
OPEN LIMIT
UP
DOWN
UP
DOWN
THE CODE SENT FROM ANY OF THE
TRANSMITTER'S THREE BUTTONS CAN BE
LEARNED BY A RECEIVER
CHOOSE ONE BUTTON ON
THE TRANSMITTER TO
CONTROL THE SPECIFIC
OPERATOR OR RECEIVER
TO PROGRAM THE CODE, WITH THE RECEIVER
IN LEARN MODE, PRESS THE TRANSMITTER BUTTON
TO SEND A SIGNAL TO THE RECEIVER
PRINTER’S INSTRUCTIONS: 
INSTR,INSTL,MCT-3 - LINEAR P/N: 222267 A - INK: BLACK - MATERIAL: 20# MEAD BOND - SIZE: 8.500” x 5.500” - SCALE: 1-1