3
Electrical Configuration and Brewing Efficiency 
 
US & Canada 
CBS-2051e
  
 
 
 
 
 
 
 
 
1.5 gallons per batch
 
Electrical 
Heater 
Voltage 
 
 
 
Maximum 
Batches per Hour* (max 11)
Config. Code 
Configuration 
(AC) 
Phase 
Wires 
KW 
Amp draw 
Cold Water 
Hot Water 
E51016 
2 X 3 KW 
120/208 
 
 
4.6 
22.1 
7.7 
11.0 
 
 
120/220 
single 
3 + ground 
5.1 
23.4 
8.6 
11.0 
 
 120/240 
  
6.1 
25.5 
10.3 
11.0 
 
CBS-2052e
  
 
 
 
 
 
 
 
 
1.5 gallons per batch 
Electrical 
Heater 
Voltage 
 
 
 
Maximum 
Batches per Hour* (max 22)
Config. Code 
Configuration 
(AC) 
Phase 
Wires 
KW 
Amp draw 
Cold Water 
Hot Water 
E52016 Option 
120/208 
   4.6 
22.4 7.7 18.6 
Universal 
2 X 3 KW 
120/220 
single 
3 + ground 
5.1 
23.7 
8.6 
20.8 
Wiring 
(Factory Setting) 
120/240  
 
6.1 25.8 
10.3  22.0 
Total 3 X 3 KW 
Option 2 
120/208 
 
 
6.9 
19.5 
11.5 
22.0 
Heaters 
3 X 3 KW 
120/220 
three 
4 + ground 
7.7 
20.6 
12.9 
22.0 
 
 120/240 
  
9.1 
22.5 
15.4 
22.0 
E52026 Option 
120/208 
   7.6 
36.9 12.8 
22.0 
Universal 
2 X 5 KW 
120/220 
single 
3 + ground 
8.5 
39.0 
14.4 
22.0 
Wiring 
 120/240 
  
10.1
42.5 
17.1 
22.0 
Total 3 X 5 KW 
Option 2 
120/208 
 
 
11.4
32.0 
19.2 
22.0 
Heaters 
3 X 5 KW 
120/220 
three 
4 + ground 
12.7
33.9 
22.0 
22.0 
 
(Factory Setting) 
120/240  
  15.1
36.9 
22.0  22.0 
 
CBS-2052e20
 
 
 
 
 
 
 
 
 
2.0 gallons per batch 
Electrical 
Heater 
Voltage 
 
 
 
Maximum 
Batches per Hour* (max 18)
Config. Code 
Configuration 
(AC) 
Phase 
Wires 
KW 
Amp draw 
Cold Water 
Hot Water 
E53016 Option 
120/208 
   4.6 
22.4 5.8 14.0 
Universal 
2 X 3 KW 
120/220 
single 
3 + ground 
5.1 
23.7 
6.5 
15.6 
Wiring 
(Factory Setting) 
120/240  
 
6.1 25.8 
7.7 
18.0 
Total 3 X 3 KW 
Option 2 
120/208 
 
 
6.9 
19.5 
8.6 
18.0 
Heaters 
3 X 3 KW 
120/220 
three 
4 + ground 
7.7 
20.6 
10.1 
18.0 
 
 120/240 
  
9.1 
22.5 
11.6 
18.0 
E53026 Option 
120/208 
   7.6 
36.9 9.6 18.0 
Universal 
2 X 5 KW 
120/220 
single 
3 + ground 
8.5 
39.0 
11.2 
18.0 
Wiring 
 120/240 
  
10.1
42.5 
12.8 
18.0 
Total 3 X 5 KW 
Option 2 
120/208 
 
 
11.4
32.0 
14.4 
18.0 
Heaters 
3 X 5 KW 
120/220 
three 
4 + ground 
12.7
33.9 
16.5 
18.0 
 
(Factory Setting) 
120/240  
  15.1
36.9 
16.5 18.0 
 
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water. 
 
Export 
CBS-2051e
  
 
 
 
 
 
 
 
 
1.5 gallons per batch
 
Electrical 
Heater 
Voltage 
 
 
 
Maximum 
Batches per Hour* (max 11)
Config. Code 
Configuration 
(AC) 
Phase 
Wires 
KW 
Amp draw 
Cold Water 
Hot Water 
E51026 
2 X 3 KW 
220 
single 
2 + ground 
5.1 
23.4 
8.9 
11.0 
 
CBS-2052e
  
 
 
 
 
 
 
 
 
1.5 gallons per batch 
Electrical 
Heater 
Voltage 
 
 
 
Maximum 
Batches per Hour* (max 22)
Config. Code 
Configuration 
(AC) 
Phase 
Wires 
KW 
Amp draw 
Cold Water 
Hot Water 
E52036 
2 X 3 KW 
220 
single 
2 + ground 
5.1 
23.7 
8.6 
20.8 
 
CBS-2052e20
 
 
 
 
 
 
 
 
 
2.0 gallons per batch 
Electrical 
Heater 
Voltage 
 
 
 
Maximum 
Batches per Hour* (max 18)
Config. Code 
Configuration 
(AC) 
Phase 
Wires 
KW 
Amp draw 
Cold Water 
Hot Water 
E53036 
2 X 3 KW 
220 
single 
2 + ground 
5.1 
23.7 
6.5 
15.6 
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.