fetco cbs-2051e ユーザーズマニュアル
3
Electrical Configuration and Brewing Efficiency
US & Canada
CBS-2051e
CBS-2051e
1.5 gallons per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 11)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E51016
2 X 3 KW
120/208
4.6
22.1
7.7
11.0
120/220
single
3 + ground
5.1
23.4
8.6
11.0
120/240
6.1
25.5
10.3
11.0
CBS-2052e
1.5 gallons per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 22)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E52016 Option
1
120/208
4.6
22.4 7.7 18.6
Universal
2 X 3 KW
120/220
single
3 + ground
5.1
23.7
8.6
20.8
Wiring
(Factory Setting)
120/240
6.1 25.8
10.3 22.0
Total 3 X 3 KW
Option 2
120/208
6.9
19.5
11.5
22.0
Heaters
3 X 3 KW
120/220
three
4 + ground
7.7
20.6
12.9
22.0
120/240
9.1
22.5
15.4
22.0
E52026 Option
1
120/208
7.6
36.9 12.8
22.0
Universal
2 X 5 KW
120/220
single
3 + ground
8.5
39.0
14.4
22.0
Wiring
120/240
10.1
42.5
17.1
22.0
Total 3 X 5 KW
Option 2
120/208
11.4
32.0
19.2
22.0
Heaters
3 X 5 KW
120/220
three
4 + ground
12.7
33.9
22.0
22.0
(Factory Setting)
120/240
15.1
36.9
22.0 22.0
CBS-2052e20
2.0 gallons per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 18)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E53016 Option
1
120/208
4.6
22.4 5.8 14.0
Universal
2 X 3 KW
120/220
single
3 + ground
5.1
23.7
6.5
15.6
Wiring
(Factory Setting)
120/240
6.1 25.8
7.7
18.0
Total 3 X 3 KW
Option 2
120/208
6.9
19.5
8.6
18.0
Heaters
3 X 3 KW
120/220
three
4 + ground
7.7
20.6
10.1
18.0
120/240
9.1
22.5
11.6
18.0
E53026 Option
1
120/208
7.6
36.9 9.6 18.0
Universal
2 X 5 KW
120/220
single
3 + ground
8.5
39.0
11.2
18.0
Wiring
120/240
10.1
42.5
12.8
18.0
Total 3 X 5 KW
Option 2
120/208
11.4
32.0
14.4
18.0
Heaters
3 X 5 KW
120/220
three
4 + ground
12.7
33.9
16.5
18.0
(Factory Setting)
120/240
15.1
36.9
16.5 18.0
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.
Export
CBS-2051e
CBS-2051e
1.5 gallons per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 11)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E51026
2 X 3 KW
220
single
2 + ground
5.1
23.4
8.9
11.0
CBS-2052e
1.5 gallons per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 22)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E52036
2 X 3 KW
220
single
2 + ground
5.1
23.7
8.6
20.8
CBS-2052e20
2.0 gallons per batch
Electrical
Heater
Voltage
Maximum
Batches per Hour* (max 18)
Config. Code
Configuration
(AC)
Phase
Wires
KW
Amp draw
Cold Water
Hot Water
E53036
2 X 3 KW
220
single
2 + ground
5.1
23.7
6.5
15.6
* Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.