VK SERIES GAS FRYERS 
VULCAN-HART                                                                                                               F-32971 Rev. F (December  2011) 
-27-
 
 
 
 
 
BOIL OUT PROCEDURE:  
 
Use the Boil Out By-Pass™ drain extension allowing the boil 
out solution to exit the fry tank without using the filtering 
system.  Do NOT allow water to run through the motor / pump.  
Drain the boil out solution into a bucket or place a high 
temperature rated water hose on the end of the drain extension 
allowing the other end to flow into a floor drain.  In Fig. 6 the 
arrow is pointing to the drain extension.  It is threaded into the 
top coupling of the oil drain tube.  Drain extension needs to be 
only hand tightened.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig. 6 
 
 
Standard Hose End 
 
Drain Tube End 
 
 
 
 
 
 
 
            
 
 
 
 
THERMAL OVERLOAD PROTECTION BUTTON: 
 
The motor/pump supplied with the 
filtering system has a thermal 
overload protection circuit that 
senses when excess heat occurs. 
This can occur due to filtering for 
long periods of time or under heavy 
load prior to discarding debris 
buildup.  If the thermal overload 
protection is tripped, wait 5 minutes 
and then reset the motor by pushing 
in the red button.  The arrow in 
Figure 7 shows the location of the 
reset button; located on the front off 
the motor / pump facing towards you. 
 
 
     Hot oil and hot 
parts can cause burns.  
 
   Fig.