SHORTED PROBE 
– If a shorted probe is detected, the heat demand is disabled and any 
running cooking cycles are cancelled. All operator buttons are disabled.  The digital control 
displays the following message: 
 
 
 
 
 
“D” Solid State – SHORTED PROBE 
 
 
 
 
 
“C” Computer – PROBE   SHORT 
 
Hi TEMPERATURE – If the temperature is greater than or equal to 415°F (212°C), the heat 
demand is disabled and any running cooking cycles are cancelled.  All operator buttons are 
disabled.  The control displays the following message: 
 
 
 
 
 
“D” Solid State – HIGH TEMP 
 
 
 
 
 
 
 
 
 
“C” Computer – HIGH TMP   HIGH TMP 
 
 
 
                                              
Troubleshooting Chart: 
 
Problem: 
    Probable 
Cause: 
 
No Heat: 
 
 
 
 
Power switch not turned on. 
      Gas 
supply 
not 
turned 
on. 
 
      Wire 
connections 
loose 
(call 
service) 
      Wires 
connections 
need 
cleaning 
      High 
Limit 
(call 
service) 
 
Insufficient or too much heat: 
 
 
Temperature not set to desired temperature. 
      High 
limit 
tripped 
(call 
service) 
      Temperature 
probe 
(call 
service) 
 
 
 
 
 
 
 
Tank will not drain: 
 
 
 
Shortening too cold. 
      Drain 
pipe 
clogged 
with 
debris. 
 
Motor / pump will not pump oil:   
 
Suction tube not seated correctly in receptacle block. 
      Filter 
screen 
is 
clogged 
and 
needs 
cleaning. 
 
 
 
 
 
 
Shortening is too thick / cold.  Heat oil up to min. 300º F. 
 
 
 
 
 
 
Discard valve lever not fully engaged either for filtering or
 
 
 
 
 
 
discarding.