POSSIBLE CAUSE
1. Not enough air
2. Gas regulator defective
3. Residues  from  manufac-
turing  processes  and  logs 
curing
1. Turning  control  knob  to  HI 
position  when  burners  are 
cold
2. Air in gas line
3. Air passageways on heater 
blocked
4. Dirty  or  partially  clogged 
burner orifice(s)
1. When heated, vapors from 
furniture polish, wax, carpet 
cleaners, etc. may turn into 
white powder residue
1. Not  enough  combustion/
ventilation air
1. Improper log placement
2. Drafts or other air currents 
affecting flame pattern
3. Air  holes  at  burner  inlet 
blocked
4. Burner flame holes 
blocked
1. Battery is not installed. Bat-
tery power is low
1. Metal  expanding  while 
heating or contracting while 
cooling
REMEDY
1. Check  burner  for  dirt  and 
debris.  If  found,  clean 
burner  (see  Cleaning  and 
Maintenance
, page 24)
2. Replace gas control
3. Problem will stop after a few 
hours of operation
1. Turn  control  knob  to  LO 
position and let warm up for 
a minute
2. Operate burners until air is 
removed  from  line.  Have 
gas  line  checked  by  local 
natural or propane/LP gas 
company
3. Observe minimum installa-
tion clearances (see pages 
9 through 11)
4. Clean burners (see Cleaning 
and Maintenance, page 24) 
or replace burner orifice
1. Turn  heater  off  when  us-
ing  furniture  polish,  wax, 
carpet  cleaners  or  similar 
products
1. Refer to Air for Combustion 
and  Ventilation  require-
ments (page 6)
1. Properly  locate  logs  (see 
Installing Logs, page 17)
2. Eliminate  source  of  drafts 
around heater
3. Clean out air holes at burn-
er inlet. Periodically repeat 
as needed
4. Remove  blockage  or  re-
place burner
1. Replace 9-volt batteries in 
receiver  and  hand  held-
remote control
1. This  is  normal  with  most 
heaters.  If  noise  is  exces-
sive,  contact  qualified  ser-
vice person
OBSERVED PROBLEM
Slight smoke or odor during 
initial operation
Heater produces a whistling 
noise when burners are lit
White powder residue form-
ing  within  burner  box  or  on 
adjacent walls or furniture
Moisture/condensation  no-
ticed on windows
Dark residue on logs inside 
of  their  fireplace  Note:  Af-
ter  removing  all  causes  of 
residue deposits, completely 
clean fireplace and appliance 
off  residue  before  reusing 
appliance
Remote  does  not  function 
(Remote-Ready  Models 
Only)
Heater produces a clicking/
ticking noise just after burners 
are lit or shut off