TROUBLESHOOTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor  cable  pinched  or 
wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode positioned 
wrong
7. Ignitor electrode broken
1. Gas  supply  turned  off  or 
equipment  shutoff  valve 
closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5. Depleted  gas  supply  (pro-
pane/LP only)
6. ODS/pilot is clogged
7. Gas regulator setting is not 
correct
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by  any  metal  or  tubing. 
Keep ignitor cable dry
3. Tighten  nut  holding  piezo 
ignitor to base panel of log 
set.  Nut  is  located  behind 
base panel
4. Replace ignitor cable
5. Replace piezo ignitor 
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while 
in PILOT position
4. Continue  holding  down 
control knob. Repeat ignit-
ing  operation  until  air  is 
removed
5. Contact  local  propane/LP 
gas company
6. Clean  ODS/pilot  (see 
Cleaning and Maintenance
page 24) or replace ODS/
pilot assembly
7. Replace gas regulator
OBSERVED PROBLEM
When  ignitor  button  is 
pressed,  there  is  no  spark 
at ODS/pilot
When  ignitor  button  is 
pressed,  there  is  spark  at 
ODS/pilot but no ignition