CLT- & CLX-1MC4 
Functional Summary 
NOTE:  Modules and terminal blocks must be 
installed into the lowest available spaces and 
continue toward the top of the enclosure. 
The Crestron
®
 1-Feed, 4-Motor Terminal Block and 
Module (CLT-1MC4 and CLX-1MC4, respectively), are 
considered a single entity and must be used together. 
They ship separately to permit termination of the field 
wiring to the CLT-1MC4 prior to installation of the CLX-
1MC4, as described in this guide. They can be mounted in 
any Crestron Automation Enclosure (CAEN-Series 
Enclosures). The terminal block is designed to terminate 
the circuit feed (HOT and NEUTRAL) and distribute the 
controlled circuits (LOAD) to the motors. The module 
connects to the terminal block and performs control of 
four bi-directional motors. The maximum load is 10 amps 
(1/2 HP) for any controlled circuit, limited to 16 amps 
total per module. The unit requires 120VAC 50/60 Hz, 1 
phase input voltage. An oversize heat sink dissipates heat 
efficiently. There are LEDs on the module to indicate 
communication to a Cresnet
®
 network, input power to the 
module, and output power to the load. 
Terminal Block & Module Locations (Single-wide Enclosure) 
MODULE
TERMINAL
BLOCK
GROUNDING
TERMINAL
BLOCK
 
 
Industry Compliance 
This product is Listed to applicable UL Standards and 
requirements by Underwriters Laboratories Inc.  
     
(E103692)
 
Terminal Block & Module Locations (Double-wide Enclosure) 
Installation 
GROUNDING TERMINAL BLOCKS
MODULE
TERMINAL BLOCK
(LEFT)
TERMINAL BLOCK
(RIGHT)
 
Terminal block and module must be mounted into a 
Crestron Automation Enclosure by a licensed electrician, 
in accordance with all national and local codes.  
CAUTION:  This equipment is for indoor use only and 
needs to be air-cooled. Mount in a well-ventilated area. 
The ambient temperature must be 32
°F to 104°F (0°C to 
40
°C). The relative humidity must be 0% to 90% (non-
condensing).  
Terminal blocks are installed along the left side of single-
wide enclosures and along the outside edges (left and 
right sides) of double-wide enclosures. Modules are 
installed along the right side of single-wide enclosures 
and side-by-side in the center of double-wide enclosures. 
When installing modules and terminal blocks in a double-
wide enclosure, be sure to invert units on the right side so 
that they can be properly wired. Refer to the illustrations 
shown in the next column when considering the location 
of terminal blocks and modules within an enclosure.  