CODE SELECTION 
EAN/UPC disable 
AA0 
 
EAN 8/EAN 13/UPC A/UPC E enable 
AA1 
AA5 
AA8 
without ADD ON 
with ADD ON 
with and without ADD ON 
EAN 8/EAN 13 enable 
AA3 
AAK 
AAL 
AA6 
without ADD ON 
with ADD ON 2 ONLY 
with ADD ON 5 ONLY 
with ADD ON 2 AND 5 
UPC A/UPC E enable 
AA4 
AAM 
AAN 
AA7 
without ADD ON 
with ADD ON 2 ONLY 
with ADD ON 5 ONLY 
with ADD ON 2 AND 5 
EAN 8 enable 
AAG0 
AAG1 
check digit transmission disable 
check digit transmission enable 
EAN 13 enable 
AAH0 
AAH1 
check digit transmission disable 
check digit transmission enable 
UPC A enable 
AAI0 
AAI1 
check digit transmission disable 
check digit transmission enable 
UPC E enable 
AAJ0 
AAJ1 
check digit transmission disable 
check digit transmission enable 
Code 39 disable 
AB0 
 
Code 39  Standard enable 
AB11xxyy 
AB12xxyy 
AB13xxyy 
no check digit control 
check digit control and transmission 
check digit control without transmission 
Code 39Full ASCII enable 
AB21xxyy 
AB22xxyy
 
no check digit control 
check digit control and transmission 
Code 2/5 family disable 
AC0 
 
Interleaved 2/5 enable 
AC11xxyy 
AC12xxyy 
AC13xxyy 
no check digit control 
check digit control and transmission 
check digit control without transmission 
Normal 2/5 5 bars enable 
AC21xxyy 
AC22xxyy 
AC23xxyy 
no check digit control 
check digit control and transmission 
check digit control without transmission  
Industrial 2/5 (IATA) enable 
AC31xxyy 
AC32xxyy 
AC33xxyy 
no check digit control 
check digit control and transmission 
check digit control without transmission 
Matrix 2/5  3 bars enable 
AC41xxyy 
AC42xxyy 
AC43xxyy 
no check digit control 
check digit control and transmission 
check digit control without transmission 
Codabar family disable 
AD0 
 
Codabar standard enable 
AD111xxyy 
AD112xxyy 
AD121xxyy 
AD122xxyy 
AD212xxyy 
no start/stop character equality control - nor transmission 
no start/stop character equality control but transmission 
start/stop character equality control but no transmission 
start/stop character equality control and transmission 
ABC Codabar no start/stop character equality control but transmission 
Code 128 family disable 
AI0 
 
Code 128 enable 
AI11 xxyy 
control without transmission of check digit 
EAN 128 enable 
AI21 xxyy 
control without transmission of check digit 
Code Length 
AILxxyy 
 
Code 93 family disable 
AK0 
 
Code 93 enable 
AK1 xxyy 
control without transmission of check digit 
PDF417 disable 
AR0 
 
PDF417 enable 
AR1 
 
Pharmacode disable 
AQ0 
 
Pharmacode enable 
AQ1xxyy 
AQ2xxyy 
forward code tx direction 
reverse code tx direction 
Overflow ratio 
AQAzz 
 
 
xxyy = ASCII numbers that define: 
xx = min. acceptable code length 
yy = max. acceptable code length 
zz = overflow ratio value 
 
The minimum code length must always be less than or equal to the maximum. 
For more detailed information on the TC1100 programmability and complete parameter list, please refer to the 
TC1100 Reference Manual. 
 
 
N2468
 
 
 
 
821000676 (Rev. H) 
 
 
 
TC1100 
CCD Scanner 
Quick Reference Guide 
 
The TC1100 is a linear CCD Scanner for OEM applications. It is available in two different versions: 
Model Description 
Order 
Number 
TC1100-1100 
CCD scanner for linear codes 
939501020 
TC1100-1200 
CCD scanner for linear and PDF417 
939501030 
Technical Specifications 
Power supply 
5 Vdc 
± 5% 
Consumption 1.5 
Interfaces 
RS232,  WEDGE,  PEN Emulation 
Max Scans/sec 
270 
Max resolution 
0,076mm (3mils) 
Readable codes: 
 
EAN/UPC, Code 39, 2/5 family, Codabar, Code 128, EAN 128, ISBT 128, Code 93, 
pharmaceutical codes, Delta IBM, Code 16K, Code 49, (Telepen, MSI/Plessey, Pharmacode 
only TC1100-1100), (Codablock-A, Codablock-F Std, Codablock-F EAN, PDF417 only 
TC1100-1200) 
Default Configuration 
Power Save 
270 scans/sec, sleep disabled, standby disabled 
Reading Parameters 
On-Line 
Code Selection 
 
Enabled codes 
 
(Only TC1100-1200)
•  Interleaved 2 of 5: Check Digit transmitted, length: min 4, max 99 
•  Code EAN8, EAN13, UPCA, UPCB: without ADD ON, Check Digit transmitted, no conversions 
•  Code 39: length: min 1, max 99 
•  Code 128: Check Digit not transmitted, length: min 1, max 99 
•  PDF417 
Data Format 
Code ID disabled, Header = <STX>, Terminator = <CR> <LF>, no Field Adjustment, Code 
length TX disabled, character replacement disabled, No Read Character = <CAN> 
Decoding Parameters 
Ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver
™ 
disabled, decoding safety = 1 read 
Enabled interface 
RS232, 9600, N, 8, 1, no handshaking, ACK/NAK disabled, RX timeout 100 ms, FIFO 
enabled, inter-character delay disabled 
Reading Diagrams 
-160
-140
-120
-100
-80
-60
-40
-20
0
20
40
60
80
100
120
140
160
0
20
40
60
80
100 120
140 160 180 200 220
240 260
280 300
320
0.13 mm
 
(5 mils)
0.30 mm
(12 mils)
0.50 mm
(20 mils)
0.20 mm
(8 mils)
0.20 mm
mm
 
-90
-80
-70
-60
-50
-40
-30
-20
-
10
0
10
20
30
40
50
60
70
80
90
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150 160 170 180
0.17 mm
(6.6 mils)
0.38 mm
(15 mils)
0.25 mm
(10 mils)
mm
 
 
Reading Diagram TC1100-1100 (code 39) 