WARNING
 EXCESSIVE AIR PRESSURE. Can cause per-
sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fl uid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.
WARNING
 STATIC SPARK. Can cause explosion result-
ing in severe injury or death. Ground pump and 
pumping system.
Sparks can ignite fl ammable material and vapors.
The pumping system and object being sprayed must be 
grounded when it is pumping, fl ushing, recirculating or 
spraying fl ammable materials such as paints, solvents, 
lacquers, etc. or used in a location where surrounding 
atmosphere is conducive to spontaneous combustion. 
Ground the dispensing valve or device, containers, hos-
es and any object to which material is being pumped.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static 
spark.
Consult local building codes and electrical codes for 
specifi c grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep infl ammables away from heat, open fl ames and 
sparks.
Keep containers closed when not in use.
WARNING
 Pump exhaust may contain contaminants. 
Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffl
  er.
Pipe the exhaust to a safe remote location when 
pumping hazardous or infl ammable materials.
Use a grounded 3/8” minimum i.d. hose between the 
pump and the muffl
  er.
WARNING
 HAZARDOUS PRESSURE. Can result in seri-
ous injury or property damage. Do not service or 
clean pump, hoses or dispensing valve while the sys-
tem is pressurized.
Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.
WARNING
 HAZARDOUS MATERIALS. Can cause serious 
injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must 
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
y
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
comply with local and national laws and safety code 
requirements.
Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.
WARNING
 EXPLOSION HAZARD. Models containing alu-
minum wetted parts cannot be used with 1,1,1-trichlo-
roethane, methylene chloride or other halogenated 
hydrocarbon solvents which may react and explode.
Check pump motor section, fl uid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.
CAUTION
 Verify the chemical compatibility of the 
pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
fl ushed or circulated. For specifi c fl uid compatibility, 
consult the chemical manufacturer.
CAUTION
 Maximum temperatures are based on me-
chanical stress only. Certain chemicals will signifi-
cantly reduce maximum safe operating temperature. 
Consult the chemical manufacturer for chemical com-
patibility and temperature limits. Refer to PUMP DATA 
on page 1 of this manual.
CAUTION
 Be certain all operators of this equipment 
have been trained for safe working practices, under-
stand it’s limitations, and wear safety goggles / equip-
ment when required.
CAUTION
 Do not use the pump for the structural sup-
port of the piping system. Be certain the system com-
ponents are properly supported to prevent stress on 
the pump parts.
Suction and discharge connections should be fl exible 
connections (such as hose), not rigid piped, and should 
be compatible with the substance being pumped.
CAUTION
 Prevent unnecessary damage to the pump. 
Do not allow pump to operate when out of material 
for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.
CAUTION
 Use only genuine ARO® replacement parts 
to assure compatible pressure rating and longest ser-
vice life.
NOTICE
 Install the pump in the vertical position. 
The pump may not prime properly if the balls do not 
check by gravity upon start-up.
NOTICE
 Re-torque all fasteners before operation. 
Creep of housing and gasket materials may cause 
fasteners to loosen. Re-torque all fasteners to insure 
against fl uid or air leakage.
NOTICE
 Replacement warning labels are available 
upon request: “Static Spark” pn \ 93616-1, Diaphragm 
Rupture” pn \ 93122.
WARNING
  =  Hazards or unsafe practices which 
could result in severe personal injury, 
death or substantial property damage.
CAUTION
  =  Hazards or unsafe practices which 
could result in minor personal injury, 
product or property damage.
NOTICE
  =  Important installation, operation or 
maintenance information.
y
y
y
y
EXCESSIVE AIR PRESSURE
STATIC SPARK
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE