Vulcan Materials wolf vcm36 ユーザーズマニュアル

ページ / 24
 
3
 - 
INSTALLATION, OPERATION AND CARE OF 
CHEESEMELTERS  
 
GENERAL 
Cheesemelters are produced with quality workmanship and material. Proper installation, 
usage and maintenance of your Cheesemelter will result in many years of satisfactory 
performance. 
 
Model 
# of Burners 
BTU/hr Input Rating 
VCM24 / CMJ24 
18,000 
VCM36 / CMJ36 
24,000 
VCM48 / CMJ48 
36,000 (2 @ 18,000) 
VCM60 / CMJ60 
42,000 (1 @ 18,000 + 1 @ 24,000) 
VCM72 / CMJ72 
48,000 (2 @ 24,000) 
INSTALLATION 
 
Before installing, verify that the type of gas (natural or propane) and the clearance 
dimensions (see page 4) agree with the specifications on the rating plate which is located 
under the crumb tray on the right side.  If the supply and equipment requirements do not 
agree, do not proceed with the installation. Contact your dealer immediately. It is 
recommended that a trained gas service technician with the necessary tools, instruments 
and skills perform the installation of the cheesemelter 
 
 
UNPACKING 
Immediately after unpacking, check for possible shipping damage.  If the cheesemelter is 
found to be damaged, save the packaging material and contact the carrier within 15 days 
of delivery. 
Before using, remove all packaging material and protective plastic from the surfaces of 
the unit. Carefully unpack your cheesemelter and make sure that no parts are discarded 
with the packaging material. A pressure regulator designed to operate with the 
cheesemelter has been supplied and must be installed before the cheesemelter is placed 
into service. (Refer to GAS PRESSURE REGULATOR INSTALLATION in this manual).