DSC pc1616 ユーザーズマニュアル

ページ / 64
5.2 Programming Worksheets
43
[501]- [554]Programmable Output Attributes
 
Program only the following attributes for the PGM options listed. All others will be ignored. PGM options are programmed in [009], 
[010] & [011].
PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):
Attribute:
1
2
3
4
5
6
7
8
ON
Not used
Not used
True Output
Follows Timer
Code Req.
Not used
Not used
Not used
OFF
Inverted 
On / Off
No Code Req.
PGM Option
[01] Residential Burglary / Fire Bell Output
Y
[02] For Future Use
[03] Sensor Reset [4][7][2]
Y
N
[04] 2-Wire Smoke Support (PGM2 only)
Y
[05] System Armed Status
Y
[06] Ready To Arm
Y
[07] Kypad Buzzer Follower Mode
Y
[08] Courtesy Pulse
Y
[11] System Tamper (all sources, zones, keypad, modules)  
Y
[12] TLM and Alarm
Y
[13] Kiss-off Output
Y
Y
[14] Ground Start Pulse
Y
Y
[15] Remote Operation (DLS Support)
Y
Y
[16] For Future Use
Y
[17] Away Armed Status
Y
[18] Stay Armed Status
Y
[19] Command Output #1, [4][7][1]
Y
Y
Y
[20] Command Output #2, [4][7][2]
Y
Y
N
[21] Command Output #3, [4][7][3]
Y
Y
N
[22] Command Output #4, [4][7][4]
Y
Y
N
[23] 24 Hr Silent Input (PGM2 only)
Y
[24] 24 Hr Audible Input (PGM2 only)
Y
[25] Delayed Burglary & Fire Output
Y
[30] Partition Status Alarm Memory Output
Y
Attribute:
1
2
3
4
5
6
 
7
8
PGM Option
ON
Serv. req.
AC Fail
TLM Fault
FTC
Zone Fault
Zone Tmp.
Zn. Low Bat.
Loss of Clock
OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
 Disabled
[09] System Trouble 
Y
Y
Y
Y
Y
Y
 
Y
Y
ON
Burg. Evnt.
Fire 
Evnt.
Panic Evnt.
Med. Evnt.
Supv. Evnt.
Priority Evnt.
Holdup Evnt.
Follows Timer*
OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
 Latched
[10] System Event 
Y
Y
Y
Y
Y
Y
Y
 
N
*If attribute [8] is turned ON, attributes [1-7] must also be turned ON.
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
 Zone 8
[29] Zone Follower
N
N
N
N
N
N
N
 
N