OPERATION
Continued
Pilot 
Burner
Thermocouple
Figure 22 - Thermocouple and Pilot
6.  With control knob pressed in, push down 
and release ignitor button. This will light 
pilot. The pilot is attached to the rear of 
the front burner. If needed, keep pressing 
ignitor button until pilot lights.
 
Note: If pilot does not stay lit, contact a 
qualified service person or gas supplier 
for repairs. Until repairs are made, light 
pilot with match 
7.  Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds, 
release control knob.
 
Note:  If  pilot  goes  out,  repeat  steps  3 
through 7. 
8.  Turn  control  knob  counterclockwise  
 to the ON position. Burner should 
light. If burner does not light, call a quali-
fied service person.
9.  To leave pilot lit and shut off burners only, 
turn control knob clockwise 
 to the 
PILOT position.
Ignitor
Figure 21 - Ignitor and Control Knob
Pilot
FROM "PILOT" POSITION
SLIGHT PUSH TO 
TURN OFF 
PULL PUSH 
ON
ON
FROM "PILOT" POSITION
SLIGHT
 PUSH 
T
TURN OFF 
PULL
 PUSH 
FROM "PILOT" POSITION
SLIGHT
 PUSH 
T
TURN OFF 
PULL
 PUSH 
ON
OFF
On
Off
OFF
OFF
Control Knob
TO TURN OFF GAS 
TO APPLIANCE
1.  Turn control knob clockwise 
 to the 
PILOT position.
2.  Press in and turn control knob clockwise 
 to the OFF position.
3.  Close  equipment  shutoff  valve  (see 
Figure 5, page 8).
CURING 
LOGS
During  the  2-3  hour  appliance  break-in  pe-
riod, you may detect an odor from appliance 
as  various  paints  and  compounds  used  in 
manufacturing of this log set cure. This is a 
normal  and  temporary  situation  that  is  not 
cause for alarm. However, you may want to 
provide extra ventilation to the room during 
this time.
To ensure proper curing of the logs:
•  Ignite  a  2"  flame  and  maintain  it  for  1 
hour.
•  Burn  logs  in  consecutive  1  hour  periods 
raising flame an additional 2" to full flame 
height for a total of three hours.
OPERATING INSTRUCTIONS 
FOR GA9050A-1
Note:  Operation  instructions  for  GA9150A 
Remote Ready Valve/Pilot Kit will be included 
with the kit.
1.  STOP!  Read  the  safety  information, 
page 13.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Press in and turn control knob clockwise 
  to the OFF position.
4.  Wait five (5) minutes to clear out any gas. 
Then  smell  for  gas  around  log  set  and 
near floor. If you smell gas, STOP! Refer 
to  the  National  Fuel  Gas  Codes, ANSI 
Z233.1/NFPA 54, Air for Combustion and 
Ventilation
. If you don’t smell gas, go to 
the next step.
5.  Turn control knob counterclockwise 
 
to the PILOT position and press in (see 
Figure 21). Keep control knob pressed in 
for five (5) seconds.
 
Note:  You  may  be  running  this  log  set 
for the first time after hooking up to gas 
supply. If so, the control knob may need 
to be pressed in for 30 seconds or more. 
This will allow air to bleed from the gas 
system.
• If  control  knob  does  not  pop  up  when 
released,  contact  a  qualified  service 
person or gas supplier for repairs.