***NOTE: For proper operation, the gas valve 
requires a nominal inlet pressure of 7 inches H
2
column for natural gas and 11 inches of H
2
O column 
for L.P. gas.  A minimum inlet pressure of 1.0 inch of 
H
2
O above the manifold setting (NAT. manifold 3.5” 
H
2
O, L.P. manifold 10” H
2
O) must be maintained with 
no pressure drop from the no load to full load 
condition.  The maximum inlet pressure must be 
maintained at or below ½ PSIG (14.5 inches H
2
column).  Refer to the chart on the left for pressure 
conversions. 
FEATURES AND OPTIONS 
 
 
STANDARD FEATURES 
 
•  Faster bake times improve time of service. 
•  Advanced Air Impingement Technology enhances bake quality and uniformity. 
•  Improved product flow during cooking reduces operation costs. 
•  Research and Applications support for continued operational success. 
•  Enodis Star service support is committed to ongoing customer satisfaction. 
•  New FastBake™ Technology designed to bake up to 35% faster than other conveyor ovens without increased 
noise levels or loss of product quality! 
 
ELECTRICAL SERVICE 
 
 
Voltage (AC) 
Phase 
Hz. 
Amps 
Single Oven 
120 
60 
6.0 
Double Stack 
120 
60 
12.0 
Triple Stack 
120 
60 
18.0 
 
 
GENERAL INFORMATION – 3255 NATURAL GAS OVENS 
 
Model 
Energy 
Power 
Voltage 
Current 
Phase 
Hz 
Gas Supply Pressure 
Inches, Water Column 
Gas Pipe 
Size (NPT) 
Single Oven 
Nat. Gas 
150,000 BTU 
120 VAC 
6 Amps 
60 Hz 
8 – 14  
1” 
Double Stack 
Nat. Gas 
300,000 BTU 
120 VAC 
12 Amps 
60 Hz 
8 – 14  
1 ¼“ 
Triple Stack 
Nat. Gas 
450,000 BTU 
120 VAC 
18 Amps 
60 Hz 
8 – 14  
1 ½“ 
 
 
GENERAL INFORMATION – 3255 PROPANE GAS OVENS 
 
Model 
Energy 
Power 
Voltage 
Current 
Phase 
Hz 
Gas Supply Pressure 
Inches, Water Column 
Gas Pipe 
Size (NPT) 
Single Oven 
L.P. Gas 
150,000 BTU 
120 VAC 
6 Amps 
60 Hz 
11.5 – 14 
¾“ 
Double Stack 
L.P. Gas 
300,000 BTU 
120 VAC 
12 Amps 
60 Hz 
11.5 – 14 
1” 
Triple Stack 
L.P. Gas 
450,000 BTU 
120 VAC 
18 Amps 
60 Hz 
11.5 – 14  
1 ¼“ 
 
 
 
 
Electrical Supply for Australia:  
Single Phase:
 240VAC, 50Hz / 20 Amp: one neutral & one earth/ground. 
Three Phase:
 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground. 
 
** In Australia, use a 10 Amp General Purpose Outlet 
 
 
 
All ovens require separate service and dedicated neutral. 
 
 
 
 
GAS PRESSURE CONVERSION CHART 
Inches of 
Water Column 
KPa m-Bar 
Millimeters of 
Water Column
 
3.5 
4.5 
10 
10.5 
11 
14 
14.5 
 
0.87 
1.12 
1.74 
2.48 
2.61 
2.73 
3.48 
3.61 
 
8.70 
11.2 
17.40 
24.87 
26.11 
27.36 
34.81 
36.05 
 
88.9 
114.3 
177.8 
254.0 
266.7 
279.4 
355.6 
368.3