Installation  must  include  equipment  shutoff 
valve, union and plugged 1/8" NPT tap. Locate 
NPT tap within reach for test gauge hook up. 
NPT tap must be upstream from heater (see 
Figure 13).
IMPORTANT:  Install  an  equipment  shutoff 
valve  in  an  accessible  location.  The  equip-
ment shutoff valve is for turning on or shutting 
off the gas to the appliance.
Check  your  building  codes  for  any  special 
requirements for locating equipment shutoff 
valve to heaters.
Apply pipe joint sealant lightly to male NPT 
threads. This will prevent excess sealant from 
going into pipe. Excess sealant in pipe could 
result in clogged heater valves.
  WARNING:  Use  pipe  joint 
sealant that is resistant to liquid 
petroleum (LP) gas.
Install sediment trap in supply line as shown 
in Figure 13. Locate sediment trap where it is 
within reach for cleaning. Locate sediment trap 
where  trapped  matter  is  not  likely  to  freeze. 
A sediment trap traps moisture and contami-
nants. This keeps them from going into heater 
controls. If sediment trap is not installed or is 
installed wrong, heater may not run properly.
IMPORTANT:  Hold  pressure  regulator  with 
wrench  when  connecting  it  to  gas  piping 
and/or fittings. Do not over tighten pipe con-
nection to regulator. The regulator body could 
be damaged.
INSTALLATION
Continued
Propane/LP 
Supply Tank
Figure 12 - External Regulator With Vent 
Pointing Down (propane/LP only)
Figure 13 - Gas Connection
* A  CSA  design-certified  equipment  shutoff 
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase 
the optional CSA design-certified equipment 
shutoff valve from your dealer.
Tee Joint
Reducer 
Bushing to 
1/8" NPT
1/8" NPT 
Plug Tap
Tee 
Joint
Pipe 
Nipple
Cap
3/8" 
NPT 
Pipe 
Nipple
Ground 
Joint 
Union
3" 
Min
Natural Gas
From Gas Meter 
(4" W.C. to 10.5" W.C.
Pressure [See 
Specifications, page 26])
Propane/LP
From External Regulator
(11" W.C. to 14" W.C. 
Pressure)
Equipment 
Shutoff 
Valve*
Test Gauge Connection*
Pressure 
Regulator
Heater 
Cabinet
Sediment 
Trap
External 
Regulator 
with Vent 
Pointing 
Down